If you specify a volume used in cascade copy as the copy source and then execute a Concurrent OPC by the acopc start or acsnap start command, it may not be possible to preserve the sequence of data updates across multiple volumes. In this case, an error message is displayed and the command terminates in an error.
If the error cannot be resolved by responding to the message, we recommend you to change the operating method of AdvancedCopy or reconfigure the system.
If you cannot change the operation method of AdvancedCopy or reconfigure the system, create a file (user.properties) that sets the sequence of data updates across multiple volumes. Then, disable sequence preservation before you retry Concurrent OPC.
Create user.properties on the following path of the server on which to execute the acopc start or acsnap start command:
In a non-cluster environment
OS Type | Location of File Creation |
---|---|
Windows | $INS_DIR\etc\prop |
Solaris | /etc/opt/FJSVccm/prop |
$INS_DIR is the "Program Directory" as specified during AdvancedCopy Manager CCM installation.
In a cluster environment
OS Type | Location of File Creation |
---|---|
Windows | $SHARE_DL:$SHARE_TOP\etc\prop |
Solaris | $SHARE_MNT/etc/opt/FJSVccm |
$SHARE_DL is the drive letter of the shared disk for AdvancedCopy Manager CCM shared data.
$SHARE_TOP is the directory that contains "Environment Directory" and "Work Directory" of the shared disk for AdvancedCopy Manager CCM shared data.
$SHARE_MNT is the mount point of the shared disk for AdvancedCopy Manager CCM shared data.
Key Name | Description |
---|---|
concurOPC.cascade | Set preservation of the sequence of data updates across multiple volumes. |
[Example for disabling sequence preservation]
concurOPC.cascade=off |
Point
For any of the storage devices below, Concurrent OPC can be executed regardless of sequence preservation of data updates. However, the sequence of data updates is not preserved across multiple volumes.
ETERNUS DX80 S2 (for earlier than V10L30 firmware)
ETERNUS DX90 S2 (for earlier than V10L30 firmware)
ETERNUS DX400 S2 series (for earlier than V10L30 firmware)
ETERNUS DX8000 S2 series (for earlier than V10L30 firmware)