Note
Shadow objects are not supported in this version.
When swapping disks of shadow disks registered with GDS Snapshot shadow classes, the shadow disks must be removed with the relevant GDS Snapshot command first. For details on GDS Snapshot commands, see "B.2 GDS Snapshot Commands."
The subsequent operations vary depending on whether the disks to be swapped are registered with disk classes.
If the disk is registered with a disk class
After removing the shadow disk, perform disk swap in the domain managing the disk class.
An error in a disk unit may not cause failures on both the related SDX and shadow objects. Even if only either of the objects fails, shadow disk removal and physical disk swap are both necessary.
If the disk is not registered with a disk class
In this situation, the disk to be swapped is a copy destination of the disk unit's copy function.
It is not necessary to perform GDS operations described in "7.3.1 Setting with GDS Management View" and "7.3.2 Using Commands." After removing the shadow disk, perform disk swap referring to the manual of the disk unit's copy function.