Top
ETERNUS SF Storage Cruiser V16.9 Operation Guide
FUJITSU Storage

1.1 Support Levels

The scope of the storage management functions of this software that can be used varies with the storage device model being used. For this software, the scope of available functions is represented as support levels, which are used as settings of the fault monitoring function and for other purposes. The table below lists the support levels that can be selected.

Table 1.1 Support Levels

Support Level

Typical Device Name

Device Detection

Fault Management

Management Window Linkage

Performance Management

SNMP Trap Monitoring (*1)

Device Polling Monitoring (*1)

Acquisition of Device Status

A

ETERNUS DX S5/S4 series
ETERNUS DX S3 series (V10L60 or later firmware)
ETERNUS AF All-Flash Arrays
ETERNUS DX200F (V10L60 or later firmware)

Automatic
(*2)

Y1

Y1

Y1
(*9)

Y1

Y1
(*5)

ETERNUS DX S3 series (earlier than V10L60 firmware)
ETERNUS DX S2 series
ETERNUS DX200F (earlier than V10L60 firmware)
PRIMERGY BX600 Fibre Channel switch blade
Brocade series
VDX series (except VDX 8770-4/VDX 8770-8/VDX 6740/VDX 6740T) (*4, *7, *8)
PRIMERGY BX Ethernet Fabric Switch (*4, *7)

Automatic
(*2)

Y1

Y1

Y1
(*10)

Y1

Y1
(*5)

B

Windows, Linux, Solaris OS, HP-UX, or AIX server node on which the Storage Cruiser's agent is already installed

Automatic
(*2)

Y1

Y1

Y1
(*10)

-

-

C

VMware vSphere

Automatic
(*2)

-

Y1

Y1
(*10)

-

-

D

NetApp FAS Series

Manual

Y1
(*4)

Y1

-

Manual setting

Y1
(*6 For data collection only)

E

VDX 8770-4, VDX 8770-8, VDX 6740, VDX 6740T, VDX series (4.0 or later firmware)
ETERNUS AX/HX series
ETERNUS AB/HB series
ETERNUS VS850 S3
NetApp FAS Series (with clustered Data ONTAP)
NetApp AFF series
ETERNUS LT series

Manual

Y1
(*4)

Y1

-

Manual setting

-

ETERNUS CS800 M1/CS800 S7/CS800 S6
ETERNUS CS2000

Manual

Y1
(*4)

Y1

-

-

-

I

Server node on which the Storage Cruiser's agent is not installed

Manual

-

-
(*3)

-

Manual setting

-

Y1: Detail information on device internal elements can be displayed.

*1: The protocols used with SNMP Trap monitoring and device polling are as follows.

Typical Device Name

Protocol Name

SNMP Trap Monitoring

Device Polling Monitoring

ETERNUS DX series (excluding the ETERNUS DX60 S2)
ETERNUS AF All-Flash Arrays
ETERNUS DX200F
PRIMERGY BX600 Fibre Channel switch blade
Brocade series
VDX series (excluding 4.0 or later firmware)
PRIMERGY BX Ethernet Fabric Switch

SNMP(SNMPv1 or SNMPv3)

ETERNUS DX60 S2
VDX series (4.0 or later firmware)
NetApp FAS Series

SNMP(SNMPv1)

ETERNUS AB/HB series

SNMP(SNMPv2c)

ping

Server node on which Storage Cruiser's agent is already installed

SNMP(SNMPv1 or SNMPv3)

unique protocol

VMware vSphere

-

VMware dedicated protocol

Other

SNMP(SNMPv1)

ping

*2: The "Detect device in subnet" function is not supported by the devices below. Specify and register the IP addresses.

*3: For devices supporting LAN, ping monitoring is enabled by specifying an IP address at manual embedding.

*4: SNMP Trap transmission must be set for each device. (This software does not automatically make said setting.)

*5: There are concerns in performance information. Refer to [Note] in "7.1.1 Performance Information Types".

*6: For NetApp FAS Series only. To refer to the performance information that is collected on the NetApp FAS Series, must be linkage with Systemwalker Service Quality Coordinator. Contact Fujitsu Technical Support for details on performance information.

*7: Only as for devices whose firmware version number is 3.0.1 or later, the performance management function is supported.

*8: The automatic registration function is not supported for devices whose firmware version number is 4.0 or later. Revise the firmware version or register manually.

*9: It takes a maximum of one minute to acquire the device information.

*10: This product acquires the device status automatically, but does not acquire the device component status automatically.