The procedure to change the FC/iSCSI/SAS port settings is as follows:
On the global navigation tab, click Storage.
The registered ETERNUS Disk storage systems are displayed on the Main pane.
On the Main pane, click the target ETERNUS Disk storage system.
On the Category pane, click Connectivity.
The port type list is displayed on the Main pane.
On the Main pane, click the digit of the Number of Ports field for the target port.
The target port list is displayed on the Main pane.
On the Main pane, check the target port checkbox.
When changing a FC port, click the target action under Port on the Action pane.
The information input screen is displayed.
Enter the necessary information, and then click Modify.
Point
The setting of the basic IP address #0 information can be changed when Multi-VLAN function of the iSCSI port is enabled.
Note
The deletion and preservation information when the FC port mode or the iSCSI port mode is changed are as follows.
Port Mode | Port Mode After Change | ||
---|---|---|---|
CA | RA | CA/RA | |
CA | - |
|
|
RA |
| - |
|
CA/RA |
|
| - |
When the FC port mode is changed, FC port setting returns to initial value.
When the iSCSI port mode is changed, iSCSI port setting returns to initial value.
Refer to [Note] in "Connectivity Management" in the Storage Cruiser Operation Guide for the conditions related to the iSCSI port setting.
If the port is iSCSI-RA, Transfer Rate and iSCSI Name cannot be changed by Web Console.
If it needs to be changed, use ETERNUS Web GUI.