Top
Systemwalker Operation Manager Troubleshooting Guide
FUJITSU Software

5.2.23 64-bit/32-bit Application Jobs End Abnormally when they are Executed [Windows Versions]

Applicable versions and levels

Action

Points to check

Is the startup mode of the job process trace mode (*1), and does either of the following apply?

*1:

Enable job object mode is not selected in the Options tab of the Define Operating Information window.

Cause

If a job is executed in a trace mode with either of the following combination, the job may end abnormally.

Action method

Change the startup mode of the job process to the job object mode.

How to set the job object mode

  1. Select Enable job object mode in the Options tab of the Define Operating Information window, and click OK.

  2. Restart Systemwalker Operation Manager.