Top
Systemwalker Operation Manager  Technical Guide
FUJITSU Software

A.2 Connection Support for Multi-server Monitoring

This section explains which versions can be monitored when servers with different versions are monitored using a multi-server monitoring client.

The following table shows the range of supported connections between different versions of Systemwalker Operation Manager.

For information about the correspondence between the version numbers in the table below and the Systemwalker Operation Manager versions for each operating system, refer to the correspondence table at the start of this appendix.

Monitored server versions: V13.2.0 - V17.0.0

Monitored server

V13.2.0

V13.3.0
V13.3.1

V13.8.0
V17.0.0

Monitoring
server

Login as the system administrator

V13.2.0

Yes

Yes

Yes
(*3)

V13.3.0
V13.3.1

Yes

Yes

Yes
(*3)

V13.8.0
V17.0.0

Yes

Yes

Yes

Login as a general user

V13.3.0
V13.3.1

No
(*1)

Yes

Yes
(*2)(*3)

V13.8.0
V17.0.0

No
(*1)

Yes

Yes
(*2)

Yes:

Can connect (and subsystem monitoring is also possible).

No:

Cannot connect.

*1:

If a general user logs in to the monitoring server and attempts to connect to a monitored server of V13.2.0 or earlier, the information cannot be obtained since there is no function for authenticating general users in monitored servers of V13.2.0 or earlier. This monitored server will be treated as "access denied" in the host summary window. Also, the job net information will not be obtainable using the Job Nets Management window.

*2:

If a general user logs in to the monitoring server and attempts to connect to a monitored server that uses the Systemwalker User Management function, the information cannot be obtained since general users cannot be authenticated in monitored servers. This monitored server will be treated as "access denied" in the host summary window. Also, the job net information will not be obtainable using the Job Nets Management window. In addition, there is no Systemwalker User Management function in V17 or later.

*3:

If the monitoring targets are only the servers for an IPv6 communication environment or a mix of servers for an IPv4 communication environment and for an IPv6 communication environment, all of the monitoring target servers, including those for the IPv4 communication environment, cannot be monitored.

If you log on from a multi-server monitoring client, a message stating that host summary information cannot be found is displayed, and the multi-server monitoring client terminates.


Connection between multi-server monitoring clients and monitoring servers


When monitoring V13.8.0 or later servers from a V13.3.1 or earlier client

If the monitoring targets are only the servers for an IPv6 communication environment or a mix of servers for an IPv4 communication environment and for an IPv6 communication environment, all of the monitoring target servers, including those for the IPv4 communication environment, cannot be monitored.

If you log on from a multi-server monitoring client, a message stating that host summary information cannot be found is displayed, and the multi-server monitoring client terminates.