Content:
The configuration file does not exist.
Corrective action:
The sfrpdupoweron command uses a common configuration file with the RPDU Shutdown Agent.
Set up the RPDU Shutdown Agent.
For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
Content:
Getting the outlet status of the Remote Power Distribution Unit has failed.
Corrective action:
Check the following points:
Check if any error occurred in the Remote Power Distribution Unit.
See the manual of the Remote Power Distribution Unit to check if any error occurred in the Remote Power Distribution Unit. Follow the manual and take the corrective action.
Check if the following items of the Remote Power Distribution Unit which is specified in the RPDU Shutdown Agent are set correctly: IP address, outlet number, user name, and password.
Check the setting of the RPDU Shutdown Agent.
For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
The normal lamp of the port connected to HUB and LAN cable is ON.
The LAN cable is correctly connected to the HUB connector or the LAN port connector of the Remote Power Distribution Unit.
The firmware is not restarted nor updated in the Remote Power Distribution Unit.
The user who accesses the Remote Power Distribution Unit has the required authority.
The required authority may not be given to the user specified for the setting of the RPDU Shutdown Agent. For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
If the above corrective actions cannot solve this error, record this message and collect information for an investigation. Then, contact field engineers.
Content:
The configuration file has an error.
Corrective action:
The sfrpdupoweron command uses a common configuration file with the RPDU Shutdown Agent.
Set up the RPDU Shutdown Agent again.
For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
If the above corrective action cannot solve this error, record this message and collect information for an investigation. Then, contact field engineers.
Content:
An invalid CF node name was specified.
Corrective action:
Check if the specified CF node name is correct.
If the specified CF node name is correct, the contents of the common configuration file with the RPDU Shutdown Agent may be incorrect.
Check the setting contents of the RPDU Shutdown Agent.
For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
If the above corrective action cannot solve this error, record this message and collect information for an investigation. Then, contact field engineers.
Content:
The ipmitool command cannot be found.
Corrective action:
Install the SUNWipmi package of the operating system.
If the above corrective action cannot solve this error, record this message and collect information for an investigation. Then, contact field engineers.
Content:
The outlet status of the Remote Power Distribution Unit was switched; however, it is still power-off.
Corrective action:
Check the following points:
Check if any error occurred in the Remote Power Distribution Unit.
See the manual of the Remote Power Distribution Unit to check if any error occurred in the Remote Power Distribution Unit. Follow the manual and take the corrective action.
The user who accesses the Remote Power Distribution Unit has the required authority.
The required authority may not be given to the user specified for the setting of the RPDU Shutdown Agent. For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
If the above corrective actions cannot solve this error, record this message and collect information for an investigation. Then, contact field engineers.
Content:
The processing for changing the outlet status of the Remote Power Distribution Unit to power-on has failed.
Corrective action:
Check the following points:
Check if any error occurred in the Remote Power Distribution Unit.
See the manual of the Remote Power Distribution Unit to check if any error occurred in the Remote Power Distribution Unit. Follow the manual and take the corrective action.
Check if the following items of the Remote Power Distribution Unit which is specified in the RPDU Shutdown Agent are set correctly: IP address, outlet number, user name, and password.
Check the setting of the RPDU Shutdown Agent.
For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
The normal lamp of the port connected to HUB and LAN cable is ON.
The LAN cable is correctly connected to the HUB connector or the LAN port connector of the Remote Power Distribution Unit.
The firmware is not restarted nor updated in the Remote Power Distribution Unit.
The user who accesses the Remote Power Distribution Unit has the required authority.
The required authority may not be given to the user specified for the setting of the RPDU Shutdown Agent. For details, see "PRIMECLUSTER Installation and Administration Guide (Oracle Solaris)."
If the above corrective actions cannot solve this error, record this message and collect information for an investigation. Then, contact field engineers.