Top
ServerView Resource Orchestrator V3.4.0 Troubleshooting
FUJITSU Software

7.7 The Member Ports Belonging to the Link Aggregation are not Updated.

Description

For a PY CB Eth Switch/IBP 10Gbps 18/8 or PY CB Eth Switch 10/40Gb 18/8+2 LAN switch blade, the LLDP and VLAN settings of the member ports of the link aggregation may mean that the information for the member ports of the link aggregation will not be updated.

Corrective Action

Perform the following corrective actions:

  1. LLDP settings of the member ports belonging to the link aggregation

    Enable the LLDP of the member port.

    When doing so, disable the [VLAN Name] in the LLDP options, and enable the other items.

  2. VLAN settings of the member ports belonging to the link aggregation

    Make the Untagged VLAN and Tagged VLAN settings for all member ports belonging to the link aggregation the same.

  3. Update the information of the LAN switch blade

    Click the [Update] button of the LAN switch blade on the server resource tree in the ROR console.