This section explains the 613XX message series.
Description
An internal error has occurred.
Corrective Action
Collect troubleshooting information and contact Fujitsu technical staff.
Description
Boot monitoring of the managed server failed.
Processing of the WWN settings for the HBA of the server may fail.
Corrective Action
Collect troubleshooting information and contact Fujitsu technical staff.
Description
Control of the PXE server failed.
Processing of the WWN settings for the HBA of the server may fail.
Corrective Action
Collect troubleshooting information and contact Fujitsu technical staff.
Description
The process of setting the WWN for the HBA of the server failed.
An internal code is displayed for %1.
Either one of the following message is displayed in %2.
HBA adapter not found
command error
TFTP error
Corrective Action
Make sure the total number of ports on HBA adapters mounted on the server is equal to or greater than the number specified on the GUI.
For Virtual Edition, refer to "6.2.7 Configuring BIOS Settings of Managed Servers" in the "Design Guide VE" and update the FC-HBA BIOS firmware if it is old.
For Cloud Edition, refer to "8.2.7 Configuring BIOS Settings of Managed Servers" in the "Design Guide CE" and update the FC-HBA BIOS firmware if it is old.
A problem related to file transfer has occurred. Check the status of the admin LAN.
Check that the IP address of the admin LAN for the managed server and other IP addresses (such as the admin LAN of iRMC or SAN storage) do not overlap.
When a message other than the above is output, or the corrective action above does not resolve this problem, collect troubleshooting information and contact Fujitsu technical staff.
Description
The port number used for service_name is already in use.
Corrective Action
Check the port number used by service_name, and change it if necessary.
For details, refer to the following:
Refer to "Appendix A Port List" in the "Design Guide VE".
Refer to "Appendix A Port List" in the "Design Guide CE".
Description
The process of 1% was aborted.
One of the following is displayed for %1.
Rebooting control domain
The reboot of control domain was aborted.
Waiting for completion of OS shutdown
The shutdown confirmation of control domain was aborted.
Waiting for completion of server boot
The power-on confirmation of server was aborted.
Recovering pci
The recovery of physical IO was aborted.
Recovering vconsole
The recovery of the port number used in domain console was aborted.
Starting io domain
The power-on of IO domain was aborted.
Starting guest domain
The power-on of guest domain was aborted.
Saving OVM spconfig
The saving of the domain configuration information to service processor was aborted.
Corrective Action
No further operation is necessary.
Reset the physical I / O device allocated to control domain and IO domain
For details on ldm command, refer to "Oracle VM Server for SPARC Administration Guide" of Oracle Company.
Reset the port number of guest domain's virtual console.
For details on ldm command, refer to "Oracle VM Server for SPARC Administration Guide" of Oracle Company.
Power on in the order of IO domain, guest domain.
For details on ldm command, refer to "Oracle VM Server for SPARC Administration Guide" of Oracle Company.
Save the domain configuration information in service processor.
For details on ldm command, refer to "Oracle VM Server for SPARC Administration Guide" of Oracle Company.
Description
The Windows PE module that is necessary for the operation was not found.
The required version of Windows PE is displayed in %1.
One of the following is displayed.
Windows PE 5(amd64)
Windows PE 3(amd64)
Windows PE 3(x86)
Corrective Action
Create the necessary Windows PE module.