Configure software related to hardware monitoring.
ServerView supports monitoring of the fan, temperature sensor, and power supply in addition to watchdog monitoring of the OS.
ServerView allows you to specify the action which will be done in the event of failure for each monitored target. For example, if "Shut down the server immediately" is selected and an error is detected, the failed node will be shut down. The ongoing operations on the failed node are then quickly switched to the standby node.
Note
No failover will be triggered by PRIMECLUSTER even if the operating system hangs up as long as communication with cluster interconnect is performed normally.
This state can be avoided by enabling watchdog timer monitoring.
See
For information about behavior setup, see the ServerView Operations Manager manual.