Top
PRIMECLUSTER  Installation and Administration Guide 4.4
FUJITSU Software

9.1.2 Changing the SF Node Weight

The following explains how to change the SF node weight after building a PRIMECLUSTER system.

Operation Procedure:

  1. Execute the following command on all the nodes to stop the shutdown facility.

    # sdtool -e
  2. Modify /etc/opt/SMAW/SMAWsf/rcsd.cfg on each node.

    Modify the following weight values.

    CFNameX,weight=weight,admIP=myadmIP: agent=SA_xxx,timeout=timeout

    Since the node weight affects the survival priority, see "5.1.2.1 Survival Priority" to determine the value to be set.

  3. Execute the following command on all the nodes to start the shutdown facility.

    # sdtool -b