Explanation
Failed to allocate memory. Processing cannot be continued.
Response
Wait until other processes are finished, or increase a swap area, then re-execute the command.
Explanation
Failed to get major number of drivename. Processing cannot be continued.
Response
Check the system environment of device driver.
Explanation
Failed to open /etc/mtab or /etc/fstab file because of errmsg. Processing cannot be continued.
Response
Check the system environment file.
Explanation
A read error occurred in the management partition.
Response
Collect a file output with FJQSS, fjsnap, or pclsnap for troubleshooting information then contact field engineers.
Explanation
Failed to get the file system configuration information in the management partition.
Response
Restore the file system configuration information. For detail, see "Chapter 5 Management Partition."
Explanation
User specified an invalid device number.
Response
Correct device number and re-execute this command.
Explanation
Failed work with unknown error.
Response
Contact field engineers.
Explanation
The file system monitoring mechanism is not operating.
Response
Make sure that the file system monitoring mechanism is running.
Explanation
A read error occurred in the management partition.
Response
Collect a file output with FJQSS, fjsnap, or pclsnap for troubleshooting information then contact field engineers.
Explanation
The obtained host ID is illegal.
Response
Collect a file output with FJQSS, fjsnap, or pclsnap for troubleshooting information then contact field engineers.
Explanation
Failed to open special or mntpoint because of errmsg. Other file systems are processed continuously.
Response
Check the arguments of command or the system environment file.
If a GDS logical volume is being used and is ACTIVE, the volume information will be displayed. Bring the volume into ACTIVE then execute the command again.
If you are operating the GFS Management View, bring the volume into ACTIVE then execute the command again.
Explanation
User specified an invalid device number (device_no).
Response
Check if the specified device number (device_no) is correct. If it is not, correct it and execute the command again.
Explanation
Configuration data of the specified partition is invalid. Other file systems are processed continuously.
Response
Check the specified partition to determine if it is an sfcfs file system.
Explanation
Failed to obtain the device data of partition special. Other file systems are processed continuously.
Response
Check the system environment to determine if partition special is correct.
Explanation
The specified partition must be a block special file but it is a character special file. Other file systems are processed continuously.
Response
Specify a block special file as a partition.
Explanation
The specified file must be a block special file or a directory. Other file systems are processed continuously.
Response
Specify a block special file or mount point directory.
Explanation
The I/O operation to the special file special failed.
Response
Check if the special file is correct.
Explanation
Failed to read normal super block data. Therefore, redundant data is read out.
Response
Delete the target file system where it is unnecessary. For details, see "11.8 Deleting" in this manual. When it is a necessary file system, restore it running a full scan with sfcfsck(8). For details, see "C.3.1 Action for I/O errors" in this manual.
Explanation
Reading the redundant volume information on special failed.
Response
Delete the target file system where it is unnecessary. For details, see "11.8 Deleting" in this manual. When it is a necessary file system, restore it running a full scan with sfcfsck(8). For details, see "C.3.1 Action for I/O errors" in this manual.