Top
PRIMECLUSTER Global Disk Services  Configuration and AdministrationGuide 4.3
FUJITSU Software

7.15.3 Operation when the LEFTCLUSTER Node Exists

If the cluster interconnect fails or the node panics, following events occur.

At this time, following processes are suspended until the LEFTCLUSTER state of the node is canceled.

See below for the maximum value of the time to suspend the processes.

[Maximum value of the time to suspend the processes (default)]

If [Timeout value of PRIMECLUSTER] below is changed from the default value, the maximum value of the time to suspend the processes can be calculated according to [Maximum value of the time to suspend the processes].

[Timeout value of PRIMECLUSTER]

[Maximum value of the time to suspend the processes]

<Maximum value of the time to suspend the processes (default) >
+ <The value of CLUSTER_TIMEOUT after removing the default value>
+ <Number of nodes> x <Timeout value of shutdown facility after removing the default value>

"Timeout value of shutdown facility" is the total value of timeout values of all the shutdown agents.

If PRIMECLUSTER Shutdown Facility (SF) fails to shut down the node and the LEFTCLUSTER state is not cleared automatically, these operations remain suspended.

To restart the processes, the LEFTCLUSTER state must be cleared manually.

For how to clear the LEFTCLUSTER state, see "PRIMECLUSTER Cluster Foundation (CF) Configuration and Administration Guide."