Command line output: details
Explanation
An error given in details occurred when executing the command.
Resolution
Identify the cause referring to the command line output. When you cannot identify the cause, contact field engineers.
Executing the command was unsuccessful. Continue?
Explanation
Executing the command was unsuccessful.
Resolution
Click <Yes> to continue, or <No> to cancel.
The following exceptions were received: details
Explanation
Exceptions given in details occurred.
Resolution
Contact field engineers.
The input object name is already defined. Change the object name.
Explanation
The input object name is already defined.
Resolution
Change the object name.
An error occurred in the log monitoring mechanism on node node. Monitoring tasks will stop. Check the status of the node and update to the latest information.
Explanation
An error such as a node crash was detected in the log monitoring mechanism.
Resolution
Verify that the node is in operation, and update to the latest information.
Reading GDS configuration information was unsuccessful on node node. Contact the system administrator.
Explanation
Reading GDS configuration information was unsuccessful on node node.
Resolution
Contact field engineers.
An invalid class name was specified. Input another name.
Explanation
An invalid character was specified for the class name.
Resolution
Click <OK> and type a class name again.
For information on characters available for class names, see "A.1.1 Object Name."
An invalid group name was specified. Input another name.
Explanation
An invalid character was specified for the group name.
Resolution
Click <OK> and type a group name again.
For information on characters available for group names, see "A.1.1 Object Name."
An invalid volume name was specified. Input another name.
Explanation
An invalid character was specified for the volume name.
Resolution
Click <OK> and type a volume name again.
For information on characters available for volume names, see "A.1.1 Object Name."
An invalid disk name was specified. Input another name.
Explanation
An invalid character was specified for the disk name.
Resolution
Click <OK> and type a disk name again.
For information on characters available for disk names, see "A.1.1 Object Name."
A system disk cannot be removed from group configuration disks.
Explanation
In system disk setting, deletion of a system disk was attempted.
Resolution
System disks cannot be deleted from group configuration disks.
You cannot add a physical disk. Up to 8 disks can be added to group configuration disks.
Explanation
In system disk setting, adding the ninth disk to group configuration disks was attempted.
Resolution
A maximum of 8-way multiplex mirroring is supported with system disks. You must limit the group configuration disks to eight.
The system disk's slice numbers are all in use. Remove at least one slice before setting the system disk.
Explanation
The number of slices on the system disk has reached the upper limit (seven) and system disk setting cannot be performed.
Resolution
Remove one or more system disk's slices, for example, with the format (1M) command before performing system disk setting.
There are unexpected device ID on node node. Exit.
Explanation
Starting GDS Management View failed due to unsupported GDS configuration information on node node.
Resolution
Contact field engineers.
The order of removing disks and groups composing the group is wrong.
Remove them in the proper order.
Explanation
A disk or group not removable was selected.
Resolution
When you remove disks and groups composing a group, you must select them in the inverse order against the added order.
The stripe width setting is wrong. Specify an integer that is the power of 2.
Explanation
An invalid character or value was specified for the stripe width.
Resolution
Click <OK>, and input a valid stripe width again.
The specified name is already in use. Input another name.
Explanation
The specified name is in use.
Resolution
Click <OK> and type an unused class name, and then click <Next>.
An invalid volume size was specified. Input a valid size.
Explanation
The specified volume size is invalid.
Resolution
Click <OK> and type a valid volume size.
When the maximum size is unknown, you can apply the maximum size to [Volume Size] by clicking <Maximum Size>.
The GDS Management View processing was aborted.
Explanation
The GDS Management View processing was aborted. A command the GDS Management View issued may be timed out.
Resolution
Collect investigation material and contact field engineers.
The status gathering was aborted.
Explanation
The process to gather object statuses was aborted. The status gathering command the GDS Management View issued may be timed out.
Resolution
Collect investigation material and contact field engineers.