Physical Disk Recognition
When any operation that changes the physical disk configuration, such as addition or deletion of disk units, is conducted during system operation, update physical disk information with new information. Execute [Update Physical Disk Information] on the [Operation] menu when:
The power of the disk unit was turned on after the system was booted.
The disk unit became unavailable for some kind of problem during system operation, but was recovered without system reboot.
The configuration of devices was changed.
Object Status Monitoring
Objects indicated as failed in GDS Management View are only those in which GDS detected errors. Even if a hardware error occurs in a disk unit, the disk unit status is indicated as normal until the disk unit is accessed and the error is detected.