Top
PRIMECLUSTER DR/PCI Hot Plug User's Guide 4.5
FUJITSU Software

1.5.2 Range of SPARC Enterprise support

The range of support varies depending on whether I/O is equipped on the system board when using DR in PRIMECLUSTER.

Product/Function

Hot swap (*1)

Hot expansion

Transfer/SB pool

Without I/O

With I/O

Without I/O

With I/O

Without I/O

With I/O

GDS

Available

Available (*2)

Available

Not available

Available

Not available

GLS

Available

Available (*3)

Available

Not available

Available

Not available

PRIMECLUSTER (*6)

Available
(*4)(*5)

Not available

Available (*4)

Not available

Available
(*4)(*5)

Not available

GDS: Global Disk Services
GLS: Global Link Services

(*1) If the system board uses Extended System Boards (XSB) and configures multiple partitions, it is necessary to remove all the Extended System Boards from the partitions.

(*2) For a system board that is connected to a GDS mirror disk, you must confirm the prerequisites for GDS operations. For details, see "Chapter 2 GDS."

(*3) For a system board where a redundant Network Interface Card (NIC) with GLS is used, you must confirm the prerequisites for GLS operations. For details, see "Chapter 3 GLS."

(*4) Observe the warnings and cautions in "Chapter 4 PRIMECLUSTER."

(*5) The kernel memory board cannot be removed (replaced or moved) on any of the node models.

(*6) For GDS/GLS, see "Product/Function" of each product.