Top
Systemwalker Desktop Keeper Reference Manual
FUJITSU Software

3.1.13 Message Output with Data Transmission Command

Backup and file transmission processing have been completed.

Event ID

1501

Type

Information

Source

SWDTLA

Cause

-

Resolution

-

Invalid parameters have been specified.

Event ID

1701

Type

Error

Source

SWDTLA

Cause

The invalid parameter is specified in the command.

Resolution

Perform the operation again after confirming the execution command.

Failed to read ini file.

Event ID

1702

Type

Error

Source

SWDTLA

Cause

  • Failed to read TRANS_SETTING.ini file. Probable causes are as follows:
    TRANS_SETTING.ini file does not exist.

  • TRANS_SETTING.ini file is corrupted.

  • Reading of TRANS_SETTING.ini file is prohibited.

  • TRANS_SETTING.ini file is used by other program.

Resolution

Confirm the TRANS_SETTING.ini file under the directory of data transmission command installation folder.

Failed to write ini file.

Event ID

1703

Type

Error

Source

SWDTLA

Cause

  • Failed to write the TRANS_SETTING.ini file. Probable causes are as follows:
    Writing for TRANS_SETTING.ini file is prohibited.

  • TRANS_SETTING.ini file is used by other programs.

Resolution

Confirm the TRANS_SETTING.ini file under the directory of data transmission command installation folder.

Settings error of data transmission command.

Event ID

1704

Type

Error

Source

SWDTLA

Cause

  • The specified folder set in Log Analyzer cannot be accessed (log temporarily saving target path folder or log transmission target path shared folder).

  • Other processes are already connected to the transmission target path shared folder and the connection processing failed.

  • The Log Analyzer settings are incorrect.

Resolution

  • Confirm causes, which affect access, such as whether the folder path is correct, folder path exists, it has the access authority or the access account/password is correct, and then set the correct value.

  • Reconfirm the contents of "Set Log Analyzer Environment on the Management Server/Master Management Server" of Installation Guide, and confirm whether the settings are correct.

  • Perform the operation again after confirming other processes are not connected to the transmission target path shared folder.

Backup processing failed.

Event ID

1705

Type

Error

Source

SWDTLA

Cause

Probable causes are as follows:

  • The transmission source information of the log analyzer settings is incorrect.

  • The data transmission command is executed twice.

Resolution

Perform the operation again after confirming the setting contents in the Log Analyzer settings.

File transmission processing failed.

Event ID

1706

Type

Error

Source

SWDTLA

Cause

The account name or password connected to the file transmission target shared folder is incorrect.

Resolution

Perform the operation again after confirming the account name and password.

Failed to write the processing completion file.

Event ID

1707

Type

Error

Source

SWDTLA

Cause

Probable causes are as follows:

  • File transmission target folder does not exist.

  • The authority to access the file transmission target folder is not given.

Resolution

Perform the operation again after confirming whether the access authority and folder of file transmission target folder exist.

Failed to read the registry.

Event ID

1708

Type

Error

Source

SWDTLA

Cause

The registry may be damaged.

Resolution

Perform the operation after confirming the registry.

Failed to write the registry.

Event ID

1709

Type

Error

Source

SWDTLA

Cause

The user who executes the data transmission command does not have Administrator authority.

Resolution

Perform the operation again after logging on as administrator.

Invalid backup period has been specified.

Event ID

1710

Type

Error

Source

SWDTLA

Cause

The invalid backup period was specified.

Resolution

Perform the operation again after confirming whether the system time of computer is incorrect and whether the data transmission command is executed twice within one day.

Version/Edition of Management Server is different.

Event ID

1711

Type

Error

Source

SWDTLA

Cause

Failed to execute the data transmission command due to different versions of the Management Server.

Resolution

Perform the operation again after confirming the version of the Management Server.

Failed to delete the file.

Event ID

1712

Type

Error

Source

SWDTLA

Cause

Failed to delete the file backed up on the Management Server.

Resolution

Manually delete the CSV files in the folder of temporarily saved log data.