Top
PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.3Redundant Line Control Function

F.2.10 SMF service using the GLS virtual IP

F.2.10.1 Startup of the service or connection to the server fails in SMF service using the GLS virtual IP address

Phenomenon:

In SMF service using the virtual IP address of Redundant Line Control function, startup of the service or connection to the server fails.

Cause and how to deal with:

The cause is that SMF service (routing or name service) requiring the virtual IP address is started up without waiting the service for Redundant Line Control function, which activates the virtual IP address.
If the service uses the virtual IP address, set as the service starts up after the virtual IP address is activated.
For details, see "3.6.10.3 Settings of the service for Redundant Line Control function".