Top
ETERNUS SF AdvancedCopy Manager V16.5 Operation Guide for Copy Control Module
FUJITSU Storage

4.6.4 acsnap start (SnapOPC+ Copy Start Command)

NAME

acsnap start - Start of SnapOPC+

SYNOPSIS

acsnap start -g copyGroup [-p copyPair | -v volumeName] [-r] [-xml]
acsnap start -g copyGroup -concur [-xml]
acsnap start -estimate -v volumeName [-xml]

DESCRIPTION

The SnapOPC+ is executed onto a specified copy group or copy pair.

If the -estimate option is specified, the monitor session of the update amount measurement starts for the specified volume.

OPTIONS

-g copyGroup

This option specifies the copy group name.

-p copyPair

This option specifies a copy pair.

-r

This option performs a copy in the reverse direction to the direction that has been specified.
The latest snap generation is selected as a copy source when the copy pair is not specified.

-v volumeName

Specify a logical volume.
If this option is specified when starting SnapOPC+ copy, the copy destination is automatically selected.
When starting the monitor session of the update amount measurement, specify a logical volume to be measured.

The following is an example of a format to specify a logical volume.

  • (1) ETERNUS name

  • (2) Logical volume number

The extent start position and the extent size can be specified.

  • (1) ETERNUS name

  • (2) Logical volume number

  • (3) Extent start position (block units)

  • (4) Extent size (number of blocks)

A character string starting with "0x" expresses a hexadecimal value.

-estimate

Specify this option when starting the monitor session of the update amount measurement.

-xml

This option specifies when displaying the result of the command execution by the XML format.

-concur

This option executes SnapOPC+ by using Concurrent OPC function.

EXIT STATUS

=0: Completed successfully
>0: Terminated abnormally

EXAMPLES

NOTES