F.2.1 Incompatibilities from 4.1A40

There is an incompatibility with the following function compared to 4.1A40.

Table F.1 Incompatibility from 4.1A40

Number

Item

1

Change in AC warning messages

2

MDS information message is added

F.2.1.1 Change in AC warning messages

Incompatibility description

For the following AC warning messages, changed the contents of details if the connection with MDS fails.

WARNING: FSP_PCLGFS_SFXFSKNL: 1104: mountpoint: Cannot mount: Connection failed: details
WARNING: FSP_PCLGFS_SFXFSKNL: 1401: mountpoint: Recovery failed: details

Before change:

errcode: Detailed number of the error

After change:

IP=ipaddress, errcode=errcode

ipaddress: The IP address where the primary MDS runs.

errcode: Detailed number of the error

Corrective action

None.

F.2.1.2 MDS information message is added

Incompatibility description

The message output to /var/adm/messages when GFS Shared File System is mounted is added.

Before change:

No message is output.

After change:

The following message is output:

NOTICE: sfcfs_mds:3022: fsid: amount of meta cache IEX is num

fsid: File system ID

num: Amount of IEX cache

Corrective action