3.3.16 Messages Output in Export Structure Information Command

Processing number of case(s): %d1 Error number of case(s): %d2

Variable information

%d1: Total number of processed information items

%d2: Number of information items that failed to upload

Cause

-

Action

Processing ended normally, so no action needs to be taken.

Incorrect syntax.

Cause

Incorrect syntax.

Action

Ensure that the specified syntax for the command argument is correct, and then execute the command again.

Output data does not exist.

Cause

There is no information to output.

Action

Processing ended normally, so no action needs to be taken.

Error occurs in input file or output file.

Cause

The specified path does not exist. Or, the path contains invalid characters, or the user does not have write privileges, so the specified file cannot be created.

Action

Ensure that the specified file name is correct and that the user that will execute the command has write privileges for the specified file path, and then execute the command again.

An instance of the command is already running. Multiple instances of the command cannot be started.

Cause

The export structure information command is already running, so a new instance cannot be started.

Action

Wait until the export structure information command currently running completes, and then execute the command again.

Database cannot be accessed.

Cause

Cannot access the database.

Action

Check if there are any abnormalities in the database, then remove the cause of the error and execute the command again.

Exceptions occurred or unable to obtain memory.

Cause

There is insufficient memory or an unexpected error occurred.

Action

Stop unnecessary programs, and then execute the command again.

Ended because exception(s) occurred. Ret=[%d]

Variable information

%d: Exception code

Cause

An unexpected error has occurred.

Action