This section explains error/warning messages regarding rcxdrcheck.
Description
When "Active-Active operation method" is selected, this message is displayed in either of the following cases.
When "Physical/Virtual L-Server switchover method" is selected
When the "-tenant" option is not specified (site switchover is specified)
Corrective Action
When performing the Active-Active operation, physical/virtual L-Server switchover and switchover per site cannot be performed.
Refer to the output message, and check the switchover method, the switchover operation method, and the command options. After that, execute the command again.
Description
When executing the command on Windows manager, this message is displayed for either of the following reasons.
The TEMP environment variable is not set
Multiple folder paths are set in the TEMP environment variable
Corrective Action
Make the %temp% folder accessible on the Windows manager by setting a single folder path to the TEMP environment variable. After that, execute the command again.
Description
The numbers of the specified switchover method or the DR switchover operation method are not correct.
Corrective Action
Execute the command again.
Check the messages displayed for inquiries.
Enter the number of desired switchover method or DR switchover operation method to continue the command.
Description
VMware vSphere CLI (vCLI) is not installed, or the path has not been added to the PATH environment variable.
Corrective Action
Check the following points regarding VMware vSphere CLI (vCLI).
If vCLI is installed in the environment used to execute the DR configuration check tool
When using the Windows manager, if the vCLI path has been added to the PATH environment variable.
Description
LUNs within the switchover scope: Replication of storage_name1(storageIP/LUN_ID),storage_name2(storageIP/LUN_ID)... has not been performed.
Corrective Action
Take corrective action for each storage_name displayed in target.
Perform storage replication
Modify the definition file to be excluded from the scope of switchover
For details on how to modify definition files, refer to "3.5 Configuring for Limiting Switchover Scope".
Move to a resource pool which is not the switchover target
Description
There are virtual storage resources, vs_name1,vs_name2..., for which processing to avoid overlapped names is performed.
Corrective Action
Modify the names of virtual storage resources displayed in "target", and ensure there are no virtual storage resources for which processing to avoid overlapped names is performed.
For details, refer to "E.1.3 Storage Preparations" in the "Design Guide CE".
Description
The rcxstorage configuration file required for physical L-Server switchover (physical OS) or physical/virtual L-Server switchover (VM host/VM guest) has not been created.
Corrective Action
Create the rcxstorage configuration file.
For details, refer to "3. Obtain the Storage Replication Information" in "4.1 Normal Operation".
Description
The definition file of VM management software required for physical/virtual L-Server switchover (VM host/VM guest) has not been created.
Corrective Action
Create the VM management software definition file.
For details, refer to "3. Create a definition file of VM management software [Physical/virtual L-Server switchover (VM host/VM guest)]" in "3.6 Creating Files Used for Switchover".
Description
The VM pool definition file required for virtual L-Server switchover (VM guest) has not been created.
Corrective Action
Create the VM pool definition file.
For details, refer to "4. Create a VM pool definition file [Virtual L-Server switchover (VM guest)]" in "3.6 Creating Files Used for Switchover".
Description
The VM management software definition file exists.
Corrective Action
Check the switchover method. For details, refer to "2.1 Switchover Methods".
When using virtual L-Server switchover (VM guest) or physical L-Server switchover (physical OS), delete the definition file of the VM management software.
Description
The VM pool definition file exists.
Corrective Action
Check the switchover method. For details, refer to "2.1 Switchover Methods".
When using physical/virtual L-Server switchover (VM host/VM guest) or physical L-Server switchover (physical OS), delete the VM pool definition file.
Description
The rcxstorage configuration file exists.
Corrective Action
Check the switchover method. For details, refer to "2.1 Switchover Methods".
When using virtual L-Server switchover (VM guest), delete the rcxstorage configuration file.
Description
After the switchover information file is exported, operations requiring the output of the switchover information file again are being performed.
Corrective Action
Execute the rcxmgrexport command again to collect the switchover information.
For details, refer to "B.1 rcxmgrexport".
Description
The resource type is type and the same name is set for the switchover target resource resource_name1 on the switchover source site and the resource resource_name2 on the switchover destination site.
Corrective Action
Change the resource name on either the switchover source site or the switchover destination site so that no resource names are duplicated between the sites.
Example
ERROR: Resource names duplicated between sites. type=Folder. Conflicted resource names are displayed as follows. |
Description
The VLAN ID of the network resource network_name1 on the switchover source site and the VLAN ID of the network resource network_name2 on the switchover destination site are the same.
Corrective Action
Recreate the network resource on either the switchover source site or the switchover destination site so that no VLAN IDs for network resources are duplicated between the sites.
For details, refer to "14.3.1 Creating New Network Resources" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Example
ERROR: Network's VLAN ID overlapped between sites. Conflicted resource names are displayed as follows. |
Description
There are no switchover target server resources displayed in "target" on the switchover destination site.
Corrective Action
Take one of the following corrective actions:
Register the server displayed in "target" to the server tree on the switchover destination site.
Correctly edit the physical server mapping definition file displayed in "target" on the switchover source site.
For details, refer to "1. Create the mapping definitions of physical servers [Physical L-Server switchover (physical OS), Physical/Virtual L-Server switchover (VM host/VM guest)]" in "3.6 Creating Files Used for Switchover".
Description
The VM host resources displayed in "target" do not exist on the switchover destination site.
Corrective Action
Take one of the following corrective actions:
Register the VM host displayed in "target" in the server tree on the switchover destination site.
Delete the server displayed in "target" from the VM pool definition file on the switchover source site.
Delete the definitions of the VM pools that are not switchover targets from the VM pool definition file and add the definitions of the VM pools that are switchover targets.
For details, refer to "4. Create a VM pool definition file [Virtual L-Server switchover (VM guest)]" in "3.6 Creating Files Used for Switchover".
Description
The admin LAN subnet of the network resource network_name1 on the switchover source site and the admin LAN subnet of the network resource network_name2 on the switchover destination site are the same.
Corrective Action
Modify the settings of the network resource on either the switchover source site or the switchover destination site so that no admin LAN subnets for network resources are duplicated between the sites.
For details, refer to "5.11 Registering Admin LAN Subnets" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Example
ERROR: Subnet of Admin LAN overlapped between sites. Conflicted resource names are displayed as follows. |
Description
The address scope of the address set resource address_set_name1 on the switchover source site and the address scope of the address set resource address_set_name2 on the switchover destination site are the same.
Corrective Action
Recreate the address set resource on either the switchover source site or the switchover destination site so that address scopes of MAC addresses and WWN address set resources do not overlap between the sites.
For details, refer to "14.6 Address Set Resources" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Example
ERROR: Address set resources overlapped between sites. Conflicted resource names are displayed as follows. |
Description
The network device resources displayed in "target" do not exist on the switchover destination site.
Corrective Action
Register the network device displayed in "target" in the network tree.
For details, refer to "5.7 Registering Network Devices" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Description
The version levels of the ROR CE managers are not the same between sites.
Corrective Action
Take one of the following corrective actions:
Update the manager.
Reconfigure the version of the switchover destination site manager to be the same as the switchover source site manager.
Description
The installation folders of the ROR CE manager are not the same between sites.
Corrective Action
Reconfigure the manager to configure the same installation folder as that of the switchover source site.
Description
ip_address1, the admin LAN IP address of the admin server on the switchover source site and ip_address2, the admin LAN IP address of the admin server on the switchover destination site, are not the same.
Corrective Action
Reconfigure the manager to use the same admin LAN IP addresses as that of the switchover source site.
Example
ERROR: Admin LAN IP address of the admin server does not match between sites. IP addresses of both sites are displayed as follows. |
Description
The same IP address is configured for the storage unit storage_unit_name1 on the switchover source site and the storage unit storage_unit_name2 on the switchover destination site.
Corrective Action
Re-create the IP address of the storage unit on either the switchover source site or the switchover destination site so that IP addresses of storage devices do not overlap between the sites.
Example
ERROR: IP address of storage units conflicted between sites. Conflicted resource names are displayed as follows. |
Description
The same values are configured for the admin LAN IP address used by the physical L-Server on the physical server server_name1 on the switchover source site and for the IP address used by the physical server server_name2 on the switchover destination site.
Corrective Action
Perform the following procedure on the switchover destination site to ensure that the IP addresses of physical servers do not overlap between sites.
Delete the physical server with the overlapping address, which was displayed in the message, from the server tree.
Register the physical server deleted from the server tree in step 1 on the server tree again, using a different IP address from the physical server on the switchover source site.
Example
ERROR: IP address of servers conflicted between sites. Conflicted resource names are displayed as follows. |
Description
The global attribute address set resource addrset is used for the tenant tenant_name1, tenant_name2....
Corrective Action
Take one of the following corrective actions:
Move the global address set resource displayed in the message to the tenant.
Modify the settings to use only address set resources specific to the tenant.
Description
The path configured for "rcxstorage_define" in the configuration file displayed in file_path cannot be found.
Corrective Action
Confirm that the path configured for "rcxstorage_define" in the configuration file displayed in file_path is correct.
Description
When executing the rcxdrcheck command, there is an error in an item checked when the -dir option is not specified.
The path configured for "rcxmgrexport_define" in the configuration file displayed in file_path cannot be found.
Corrective Action
Confirm that the path configured for "rcxmgrexport_define" in the configuration file displayed in file_path is correct.
Description
The path configured for "salvage_define" in the configuration file displayed in file_path cannot be found.
Corrective Action
Confirm that the path configured for "salvage_define" in the configuration file displayed in file_path is correct.
Description
There is an error in the item checked when automatic takeover of configuration files is enabled.
There is an error in the content configured for "DR Operation Method" in the configuration file displayed in file_path.
Corrective Action
Confirm that one of the following values is correctly configured for "DR Operation Method" in the configuration file displayed in file_path.
For the Active-Active DR operation method: DR_operation_method=1
For the Active-Standby DR operation method: DR_operation_method=2
For details on automatic takeover of configuration files, refer to "3.3 Manager Installation and Configuration".
Description
There is an error in the item checked when automatic takeover of configuration files is enabled.
There is no value configured for "DR Operation Method" in the configuration file displayed in file_path.
Corrective Action
Confirm that one of the following values is correctly configured for "DR Operation Method" in the configuration file displayed in file_path.
For the Active-Active DR operation method: DR_operation_method=1
For the Active-Standby DR operation method: DR_operation_method=2
For details on automatic takeover of configuration files, refer to "3.3 Manager Installation and Configuration".
Description
There is an error in the content configured for "Config File Switchover" in the configuration file displayed in file_path.
Corrective Action
Confirm that the following value is correctly configured for "Config File Switchover" in the configuration file displayed in file_path.
When enabling automatic takeover of configuration files: config_file_switchover=true
For details on automatic takeover of configuration files, refer to "3.3 Manager Installation and Configuration".
Description
There is the following inconsistency between the switchover source and destination sites:
Switchover source site
Disk resources disk1, disk2, ... which are linked to the virtual storage "vm-disk-vstorage" are configured as switchover targets.
Switchover destination site
Disk resources with the same name as disk1, disk2, ... do not exist in the ROR database.
Corrective Action
Register the disk resources disk1, disk2, ... displayed for "target" on the switchover destination site.
For the registration procedure, refer to "Configuration When Performing Virtual L-Server Switchover (VM Guest)" in "3.4 Configuring Managed Resources".
Description
There is an error in the item checked during physical server switchover (physical OS) or physical/virtual L-Server switchover (VM host/VM guest).
There is no value configured for "rcxstorage_define" in the configuration file displayed in file_path.
Corrective Action
When the situation is either of the following cases, configure the path to the switchover information folder for "rcxstorage_define" in the configuration file displayed for file_path.
Physical L-Server switchover (physical OS) with Configuring Automatic Collection of Switchover Information enabled
Physical/virtual L-Server switchover (VM host/VM guest) with Configuring Automatic Collection of Switchover Information enabled
Description
When executing the rcxdrcheck command, there is an error in an item checked when the -dir option is not specified.
There is no value configured for "rcxmgrexport_define" in the configuration file displayed in file_path.
Corrective Action
When the situation is either of the following cases, configure the path to the switchover information folder for "rcxmgrexport_define" in the configuration file displayed for file_path.
When Configuring Automatic Collection of Switchover Information is enabled
When executing the rcxmgrexport command without the -dir option specified
For details on the rcxmgrexport command, refer to "B.1 rcxmgrexport".
Description
There is no value configured for "salvage_define" in the configuration file displayed in file_path.
Corrective Action
For "salvage_define" in the configuration file displayed in the file_path, enter the path to be specified when using the rcxrecovery -salvage command.
For details on the rcxrecovery -salvage command, refer to "B.2 rcxrecovery".
Description
There is no value configured for "Config File Switchover" in the configuration file displayed in file_path.
Corrective Action
When enabling automatic takeover of configuration files, configure "config_file_switchover=true" for "Config File Switchover" in the configuration file displayed in file_path.
For details on automatic takeover of configuration files, refer to "3.3 Manager Installation and Configuration".
Description
Different values are not configured for the software ID prefixes of the two sites.
Corrective Action
Execute the software ID batch conversion command, "cfmg_changesoftwareid", and then configure different software ID prefixes for each site.
For details, refer to "Appendix A Settings for Software ID Prefixes".
Description
The global attribute network resource net is used for the tenant tenant_name1, tenant_name2....
Corrective Action
Take one of the following corrective actions:
Move the global network resource displayed in the message to the tenant.
Modify the settings to only use the network resources specific to the tenant.
During switchover, lock all tenants which use the corresponding network resources.
For details, refer to "4.2.2 Locking the Resources and Exporting the Configuration Information [Switchover Source Site]".
Description
When performing physical L-Server switchover (physical L-Server), the image file storage folder is not modified to "switchover_information_folder\Image".
Corrective Action
Configure "switchover_information_folder\Image" for the image file storage folder of the physical L-Server, and replicate the folder to the switchover destination site. Execute the following command to modify the image file storage folder of the physical L-Server to "switchover_information_folder\Image".
[Windows Manager]
>Installation_folder\SVROR\Manager\bin\rcxadm mgrctl stop <RETURN> |
[Linux Manager]
# /opt/FJSVrcvmr/bin/rcxadm mgrctl stop <RETURN> |
For details, refer to "6.7 Changing the Image Folder Location" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Description
The resource type is type and the same name is set for the switchover target resource resource_name1 on the switchover source site and the resource resource_name2 on the switchover destination site.
Corrective Action
When resource_name1 and resource_name2 are different resources, change the resource name on either the switchover source site or the switchover destination site so that resource names do not overlap between the sites.
Example
WARNING: Resource names duplicated between sites. type=VirtualStorage. Conflicted resource names are displayed as follows. |
Description
When performing switchover in Active-Active operation, the resource displayed in "target" is required for switchover, but registration from the resource pool in the switchover destination site is not canceled.
Corrective Action
Unregister the resource shown in "target" from the resource pool in the switchover source site in advance.
Description
There are no switchover target server resources displayed in "target" on the switchover destination site.
Corrective Action
When the server resources displayed for "target" are out of the switchover scope, no action is necessary.
When the server resources displayed for "target" are included in the switchover scope, perform one of the following corrective actions:
Register the server displayed in "target" to the server tree on the switchover destination site.
Correctly edit the physical server mapping definition file displayed in "target" on the switchover source site.
Refer to "2.4 Limitation of Switchover Scope and Additional Recovery" for information on limitation of switchover scopes.
For details on how to edit mapping definition files, refer to "1. Create the mapping definitions of physical servers [Physical L-Server switchover (physical OS), Physical/Virtual L-Server switchover (VM host/VM guest)]" in "3.6 Creating Files Used for Switchover".
Description
The VM host resources displayed in "target" do not exist on the switchover destination site.
Corrective Action
When the VM host resources displayed for "target" are out of the switchover scope, no action is necessary.
When the VM host resources displayed for "target" are included in the switchover scope, perform one of the following corrective actions:
Register the VM host displayed in "target" in the server tree on the switchover destination site.
Delete the server displayed in "target" from the VM pool definition file on the switchover source site.
Delete the definitions of the VM pools that are not switchover targets from the VM pool definition file and add the definitions of the VM pools that are switchover targets.
Refer to "2.4 Limitation of Switchover Scope and Additional Recovery" for information on limitation of switchover scopes.
For details on how to edit the VM pool definition file, refer to "4. Create a VM pool definition file [Virtual L-Server switchover (VM guest)]" in "3.6 Creating Files Used for Switchover".