This section explains the operation for modifying FC path configurations of physical L-Servers for NS Appliance.
This operation is only possible when physical L-Servers for NS Appliances are created using SAN storage.
Stop all the NS Appliances on the physical L-Server for NS Appliance.
For details on how to stop an NS Appliance, refer to "4.2.2 Stopping NS Appliances".
Stop the physical L-Server for NS Appliance.
For details on how to stop physical L-Servers, refer to "17.1.2 Stopping an L-Server" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Right-click the target L-Server in the orchestration tree.
In the displayed menu, select [Modify]-[Modify Specification].
In the displayed menu, select [Indicates the settings for when the server starts]-[FC path].
When changing the FC path configuration from a single path configuration to a multi-path configuration
Uncheck the "single path-mode" checkbox.
When changing the FC path configuration from a multi-path configuration to a single path configuration
Check the "single path-mode" checkbox.
Click the [OK] button.
Start a physical L-Server for NS Appliance.
For details on how to start physical L-Servers, refer to "17.1.1 Starting an L-Server" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".
Execute the rcxnetworkservice fcctl command.
Executing this command restarts the physical L-Server for NS Appliance.
For details on this command, refer to "A.1 rcxnetworkservice".
Starts an NS Appliance.
For details on how to start an NS Appliance, refer to "4.2.1 Starting NS Appliances".