Top
ServerView Resource Orchestrator Cloud Edition V3.2.0 NS Option Instruction
FUJITSU Software

1.4.3 Admin LAN NIC Configuration

This section explains the admin LAN NIC configuration of physical L-Servers for NS Appliance.

It is necessary to configure the NICs which are used for the admin LAN of the physical L-Server for NS Appliance in a redundant configuration.

If NICs are not in a redundant configuration, NS Appliance creation will fail.

The combinations of NICs that can be configured in redundant configurations are as follows:

Table 1.16 When Using PRIMERGY BX900 Chassis

Blade Server

NIC in Redundant Configuration
(Physical Network Adapter Number)

Remarks

PRIMERGY BX924 S2
PRIMERGY BX924 S3
PRIMERGY BX924 S4

1, 2

NIC1 and NIC2 of the on-board NICs are used as the NICs of the admin LAN and public LAN by performing redundancy.


Table 1.17 When Using Rack Mount Servers

Rack Mount Server

NIC in Redundant Configuration
(Physical Network Adapter Number)

Remarks

PRIMERGY RX300 S7
PRIMERGY RX300 S8

2 arbitrary NICs

NIC1 and NIC2 of the on-board NICs are used as the NICs of the admin LAN and public LAN by performing redundancy.
Also, NIC3 and NIC4 of a LAN expansion card NIC are used by performing redundancy.