The restrictions common to all editions are as below.
No. | Restriction | Corrective Action | Release Schedule |
---|---|---|---|
1 | Extended Partitioning cannot be used on PRIMEQUEST 2000 series servers. | None. | Not yet determined |
2 | PRIMERGY RX4770 M1 cannot be used as physical servers. | None. | Next release |
3 | If the VIOM server profile that configures a virtual address to be allocated to the first onboard NIC, is allocated to a BX2560 M1, when server switchover or failback is performed, the second onboard NIC with no virtual address allocated cannot be used due to port blockage. | For this reason, ensure that the VIOM server profile to be allocated to a BX2560 M1 allocates virtual addresses to all of the onboard NICs. | V3.2.0 (T011583LP-01/T011582WP-01) |
4 | When using a PRIMERGY BX2560 M1 as a physical server, the UMC function cannot be used. | None. | V3.2.0 (T011583LP-01/T011582WP-01) |
5 | The following models of the PRIMEQUEST 2000 series cannot be used:
| None. | V3.2.0 (T011583LP-02/T011582WP-02) |
6 | VLANs configured using AMPP or VMware-aware Network Automation of Brocade VDX are not displayed on the Resource Details window or NetworkViewer. | None. | V3.2.0 (T011583LP-06/T011582WP-05) |
7 | The following models cannot be used for Linux manager environments.
| None. | Next release |