Details of Modification
The definition format of the monitoring method in the XML definition for network configuration information has been changed.
V3.2.0 (T011583LP-03/T011582WP-03)
<Monitoring method="Monitoring method"> |
Element Name | Description | Acceptable Value or Example |
---|---|---|
Monitoring method (Monitoring method) | Monitoring method | Specify the monitoring method for network devices. Specify one of the following values:
When omitted, "1" is specified. |
V3.2.0 (T011583LP-04/T011582WP-04)
<Monitoring> |
Element Name | Description | Acceptable Value or Example |
---|---|---|
Monitoring method information (Methods) | A set of information about the monitoring method | Specify one or more Method elements to specify the monitoring method. When omitted, one of the following values is specified:
|
Monitoring method (Method) | Monitoring method | Specify the monitoring method for network devices. Specify one of the following values:
When omitted, network device monitoring is set to "Do not perform monitoring". To set multiple monitoring methods, specify multiple entries of this element. |
Corrective Action
No action is required.
Import is still possible using the previous format of Monitoring method (Monitoring method).
When both the Monitoring method before change (Monitoring method) and the Monitoring method information (Methods) after change are specified, the value specified for Monitoring method information (Methods) is regarded as a valid value.
When importing network configuration information that was exported using the format after change into the manager in an environment existing since before occurrence of this incompatibility, modify the definition for monitoring method, from the format using Monitoring method information (Methods) to the format using Monitoring method (Monitoring method) in the network configuration information before importing it.