Top
ServerView Resource Orchestrator Cloud Edition V3.1.2 DR Option Instruction
FUJITSU Software

C.3 Messages Regarding rcxdrcheck

This section explains error/warning messages regarding rcxdrcheck.

ERROR: This type of DR switchover is not supported.

Description

When "Active-Active operation method" is selected, this message is displayed in either of the following cases.

  • When "Physical/Virtual L-Server switchover method" is selected

  • When the "-tenant" option is not specified (site switchover is specified)

Corrective Action

When performing the Active-Active operation, physical/virtual L-Server switchover and switchover per site cannot be performed.
Refer to the output message, and check the switchover method, the switchover operation method, and the command options. After that, execute the command again.

ERROR: The check tool cannot be processed because the temporary folder %temp% cannot be accessed. Please set the TEMP environment variable of current user correctly, then rerun the check tool.

Description

When executing the command on Windows manager, this message is displayed for either of the following reasons.

  • The TEMP environment variable is not set

  • Multiple folder paths are set in the TEMP environment variable

Corrective Action

Make the %temp% folder accessible on the Windows manager by setting a single folder path to the TEMP environment variable. After that, execute the command again.

ERROR: The specified value is invalid.

Description

The numbers of the specified switchover method or the DR switchover operation method are not correct.

Corrective Action

  1. Execute the command again.

  2. Check the messages displayed for inquiries.

  3. Enter the number of desired switchover method or DR switchover operation method to continue the command.

ERROR: Replication check of vmware datastores cannot be performed. Detail: vCLI is not installed or path of vCLI has not been set to environment variable.

Description

VMware vSphere CLI(vCLI) is not installed, or the path has not been added to the PATH environment variable.

Corrective Action

Check the following points regarding VMware vSphere CLI(vCLI).

  • If vCLI is installed in the environment used to execute the DR configuration check tool

  • When using the Windows manager, if the vCLI path has been added to the PATH environment variable.

ERROR: Storage resources are not replicated.target=storage_name1(storageIP/LUN_ID),storage_name2(storageIP/LUN_ID)...

Description

LUNs within the switchover scope: Replication of storage_name1(storageIP/LUN_ID),storage_name2(storageIP/LUN_ID)... has not been performed.

Corrective Action

Take corrective action for each storage_name displayed in target.

  • Perform storage replication

  • Modify the definition file to be excluded from the scope of switchover

    For details on how to modify the definition file, refer to "3.5 Configuring for Limiting Switchover Scope".

  • Move to a resource pool which is not the switchover target

ERROR: Virtual storage resources with additional numbers at the end of the name exist on the switchover source site.target=vs_name1,vs_name2...

Description

There are virtual storage resources, vs_name1,vs_name2..., for which processing to avoid overlapped names is performed.

Corrective Action

Modify the names of virtual storage resources displayed in "target", and ensure there are no virtual storage resources for which processing to avoid overlapped names is performed.
For details, refer to "E.1.3 Storage Preparations" in the "Design Guide CE".

ERROR: Output of rcxstorage not found.

Description

The rcxstorage configuration file required for physical L-Server switchover (physical OS) or physical/virtual L-Server switchover (VM host/VM guest) has not been created.

Corrective Action

Create the rcxstorage configuration file.
For details, refer to "4. Obtain the Storage Replication Information" in "4.1 Normal Operation".

ERROR: VM management software definition file not found.

Description

The definition file of VM management software required for physical/virtual L-Server switchover (VM host/VM guest) has not been created.

Corrective Action

Create the VM management software definition file.
For details, refer to "3. Create a definition file of VM management software [Physical/virtual L-Server switchover (VM host/VM guest)]" in "3.6 Creating Files Used for Switchover".

ERROR: VM pool definition file not found.

Description

The VM pool definition file required for virtual L-Server switchover (VM guest) has not been created.

Corrective Action

Create the VM pool definition file.
For details, refer to "4. Create a VM pool definition file [Virtual L-Server switchover (VM guest)]" in "3.6 Creating Files Used for Switchover".

ERROR: VM management software definition file exists.

Description

The VM management software definition file exists.

Corrective Action

Check the switchover method. For details, refer to "2.1 Switchover Methods".
When using virtual L-Server switchover (VM guest) or physical L-Server switchover (physical OS), delete the definition file of the VM management software.

ERROR: VM pool definition file exists.

Description

The VM pool definition file exists.

Corrective Action

Check the switchover method. For details, refer to "2.1 Switchover Methods".
When using physical/virtual L-Server switchover (VM host/VM guest) or physical L-Server switchover (physical OS), delete the VM pool definition file.

ERROR: Output of rcxstorage exists.

Description

The rcxstorage configuration file exists.

Corrective Action

Check the switchover method. For details, refer to "2.1 Switchover Methods".
When using virtual L-Server switchover (VM guest), delete the rcxstorage configuration file.

ERROR: Exported configuration information is out of date.

Description

After the switchover information file is exported, operations requiring the output of the switchover information file again are being performed.

Corrective Action

Execute the rcxmgrexport command again to collect the switchover information.
For details, refer to "B.1 rcxmgrexport".

ERROR: Resource names duplicated between sites. type=type. Conflicted resource names are displayed as follows.
Switchover Source Site: resource_name1, Switchover Destination Site: resource_name2

Description

The resource type is type and the same name is set for the switchover target resource resource_name1 on the switchover source site and the resource resource_name2 on the switchover destination site.

Corrective Action

Change the resource name on either the switchover source site or the switchover destination site so that no resource names are duplicated between the sites.

Example

ERROR: Resource names duplicated between sites. type=Folder. Conflicted resource names are displayed as follows.
Switchover Source Site: /VMHostPool, Switchover Destination Site: /VMHostPool
ERROR: Resource names duplicated between sites. type=Network. Conflicted resource names are displayed as follows.
Switchover Source Site: /NetworkPoolDR/network1, Switchover Destination Site: /NetworkPool/network1
Switchover Source Site: /TenantA/TenantNetworkPool/network2, Switchover Destination Site: /TenantB/TenantNetworkPool/network2
ERROR: Resource names duplicated between sites. type=Usergroup. Conflicted resource names are displayed as follows.
Switchover Source Site: monitor, Switchover Destination Site:monitor
Switchover Source Site: test, Switchover Destination Site:test

ERROR: Network's VLAN ID overlapped between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: network_name1, Switchover Destination Site: network_name2

Description

The VLAN ID of the network resource network_name1 on the switchover source site and the VLAN ID of the network resource network_name2 on the switchover destination site are the same.

Corrective Action

Recreate the network resource on either the switchover source site or the switchover destination site so that no VLAN IDs for network resources are duplicated between the sites.
For details, refer to "14.3.1 Creating New Network Resources" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

Example

ERROR: Network's VLAN ID overlapped between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: /NetworkPoolDR/network1, Switchover Destination Site: /NetworkPool/network2
Switchover Source Site: /TenantA/TenantNetworkPool/network3, Switchover Destination Site: /TenantB/TenantNetworkPool/network4

ERROR: Subnet of Admin LAN overlapped between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: network_name1, Switchover Destination Site: network_name2

Description

The admin LAN subnet of the network resource network_name1 on the switchover source site and the admin LAN subnet of the network resource network_name2 on the switchover destination site are the same.

Corrective Action

Modify the settings of the network resource on either the switchover source site or the switchover destination site so that no admin LAN subnets for network resources are duplicated between the sites.
For details, refer to "5.11 Registering Admin LAN Subnets" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

Example

ERROR: Subnet of Admin LAN overlapped between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: /NetworkPoolDR/network1, Switchover Destination Site: /NetworkPool/network2
Switchover Source Site: /TenantA/TenantNetworkPool/network3, Switchover Destination Site: /TenantB/TenantNetworkPool/network4

ERROR: Address set resources overlapped between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: address_set_name1, Switchover Destination Site: address_set_name2

Description

The address scope of the address set resource address_set_name1 on the switchover source site and the address scope of the address set resource address_set_name2 on the switchover destination site are the same.

Corrective Action

Recreate the address set resource on either the switchover source site or the switchover destination site so that address scopes of MAC addresses and WWN address set resources do not overlap between the sites.
For details, refer to "14.6 Address Set Resources" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

Example

ERROR: Address set resources overlapped between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: /AddressPool/mac1, Switchover Destination Site: /AddressPool/mac2
Switchover Source Site: /TenantA/TenantAddressPool/wwn1, Switchover Destination Site: /TenantB/TenantAddressPool/wwn2

ERROR: Server resources have not been registered on the destination site.target= server_name1,server_name2...

Description

There are no switchover target server resources displayed in "target" on the switchover destination site.

Corrective Action

Take one of the following corrective actions:

  • Register the server displayed in "target" to the server tree on the switchover destination site.

  • Correctly edit the physical server mapping definition file displayed in "target" on the switchover source site.

For details, refer to "1. Create the mapping definitions of physical servers [Physical L-Server switchover (physical OS), Physical/Virtual L-Server switchover (VM host/VM guest)]" in "3.6 Creating Files Used for Switchover".

ERROR: VM host resources have not been registered on the destination site.target= host1,host2...

Description

The VM host resources displayed in "target" do not exist on the switchover destination site.

Corrective Action

Take one of the following corrective actions:

  • Register the VM host displayed in "target" in the server tree on the switchover destination site.

  • Delete the server displayed in "target" from the VM pool definition file on the switchover source site.

  • Delete the definitions of the VM pools that are not switchover targets from the VM pool definition file and add the definitions of the VM pools that are switchover targets.

For details, refer to "4. Create a VM pool definition file [Virtual L-Server switchover (VM guest)]" in "3.6 Creating Files Used for Switchover".

ERROR: Network devices have not been registered on the destination site.target= net_dev1,net_dev2...

Description

The network device resources displayed in "target" do not exist on the switchover destination site.

Corrective Action

Register the network device displayed in "target" in the network tree.
For details, refer to "5.7 Registering Network Devices" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

ERROR: ROR version does not match between sites.

Description

The version levels of the ROR CE managers are not the same between sites.

Corrective Action

Take one of the following corrective actions:

  • Update the manager.

  • Reconfigure the version of the switchover destination site manager to be the same as the switchover source site manager.

ERROR: Location of ROR installation folder does not match between sites.

Description

The installation folders of the ROR CE manager are not the same between sites.

Corrective Action

Reconfigure the manager to configure the same installation folder as that of the switchover source site.

ERROR: Admin LAN IP address of the admin server does not match between sites. IP addresses of both sites are displayed as follows.
Switchover Source Site: ip_address1, Switchover Destination Site: ip_address2

Description

ip_address1, the admin LAN IP address of the admin server on the switchover source site and ip_address2, the admin LAN IP address of the admin server on the switchover destination site, are not the same.

Corrective Action

Reconfigure the manager to use the same admin LAN IP addresses as that of the switchover source site.

Example

ERROR: Admin LAN IP address of the admin server does not match between sites. IP addresses of both sites are displayed as follows.
Switchover Source Site:10.167.223.100, Switchover Destination Site: 10.167.223.101

ERROR: IP address of storage units conflicted between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: storage_unit_name1, Switchover Destination Site: storage_unit_name2

Description

The same IP address is configured for the storage unit storage_unit_name1 on the switchover source site and the storage unit storage_unit_name2 on the switchover destination site.

Corrective Action

Re-create the IP address of the storage unit on either the switchover source site or the switchover destination site so that IP addresses of storage devices do not overlap between the sites.

Example

ERROR: IP address of storage units conflicted between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: storage_unit_name1, Switchover Destination Site: storage_unit_name2
Switchover Source Site: storage_unit_name3, Switchover Destination Site: storage_unit_name4

ERROR: IP address of servers conflicted between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: server_name1, Switchover Destination Site: server_name2

Description

The same values are configured for the admin LAN IP address used by the physical L-Server on the physical server server_name1 on the switchover source site and for the IP address used by the physical server server_name2 on the switchover destination site.

Corrective Action

Perform the following procedure on the switchover destination site to ensure that the IP addresses of physical servers do not overlap between sites.

  1. Delete the physical server with the overlapping address, which was displayed in the message, from the server tree.

  2. Register the physical server deleted from the server tree in step 1 on the server tree again, using a different IP address from the physical server on the switchover source site.

Example

ERROR: IP address of servers conflicted between sites. Conflicted resource names are displayed as follows.
Switchover Source Site: server_name1, Switchover Destination Site: server_name2
Switchover Source Site: server_name3, Switchover Destination Site: server_name4

ERROR: Global addressset resource addrset is used by tenant_resource.

Description

The global attribute address set resource addrset is used for the resource tenant_resource in the tenant.

Corrective Action

Take one of the following corrective actions:

  • Move the global address set resource displayed in the message to the tenant.

  • Modify the settings to use only address set resources specific to the tenant.

ERROR: Software ID prefix has not been changed properly.

Description

Different values are not configured for the software ID prefixes of the two sites.

Corrective Action

Execute the software ID batch conversion command, "cfmg_changesoftwareid", and then configure different software ID prefixes for each site.
For details, refer to "Appendix A Settings for Software ID Prefixes".

WARNING: Global network resource net is used by tenant_resource.

Description

The global attribute network resource net is used for the resource tenant_resource in the tenant.

Corrective Action

Take one of the following corrective actions:

WARNING: The location of image file folder is not set correctly.

Description

When performing physical L-Server switchover (physical L-Server), the image file storage folder is not modified to "switchover_information_folder\Image".

Corrective Action

Configure "switchover_information_folder\Image" for the image file storage folder of the physical L-Server, and replicate the folder to the switchover destination site. Execute the following command to modify the image file storage folder of the physical L-Server to "switchover_information_folder\Image".

[Windows Manager]

>Installation_folder\SVROR\Manager\bin\rcxadm mgrctl stop <RETURN>
>Installation_folder\SVROR\Manager\bin\rcxadm imagemgr set -attr imagedir=switchover_information_folder\Image <RETURN>
>Installation_folder\SVROR\Manager\bin\rcxadm mgrctl start <RETURN>

[Linux Manager]

# /opt/FJSVrcvmr/bin/rcxadm mgrctl stop <RETURN>
# /opt/FJSVrcvmr/bin/rcxadm imagemgr set -attr imagedir=switchover_information_folder\Image <RETURN>
# /opt/FJSVrcvmr/bin/rcxadm mgrctl start <RETURN>

For details, refer to "6.7 Changing the Image Folder Location" in the "User's Guide for Infrastructure Administrators (Resource Management) CE".

WARNING: Resource names duplicated between sites. type=type. Conflicted resource names are displayed as follows.
Switchover Source Site: resource_name1, Switchover Destination Site: resource_name2

Description

The resource type is type and the same name is set for the switchover target resource resource_name1 on the switchover source site and the resource resource_name2 on the switchover destination site.

Corrective Action

When resource_name1 and resource_name2 are different resources, change the resource name on either the switchover source site or the switchover destination site so that resource names do not overlap between the sites.

Example

WARNING: Resource names duplicated between sites. type=VirtualStorage. Conflicted resource names are displayed as follows.
Switchover Source Site: /StoragePool/datastore1, Switchover Destination Site: datastore1
Switchover Source Site: /TenantA/TenantStoragePool/datastore2, Switchover Destination Site: datastore2

WARNING: Resources have not been unregistered on switchover destination site.target= resource_name1,resource_name2

Description

When performing switchover in Active-Active operation, the resource displayed in "target" is required for switchover, but registration from the resource pool in the switchover destination site is not canceled.

Corrective Action

Unregister the resource shown in "target" from the resource pool in the switchover source site in advance.

WARNING: Server resources have not been registered on the destination site.target=
server_name1,server_name2...

Description

There are no switchover target server resources displayed in "target" on the switchover destination site.

Corrective Action

When the server resource displayed in "target" is not in the scope of switchover, no corrective action is required.

When the server resource displayed in "target" is in the scope of switchover, take one of the following corrective actions:

  • Register the server displayed in "target" to the server tree on the switchover destination site.

  • Correctly edit the physical server mapping definition file displayed in "target" on the switchover source site.

Refer to "2.4 Limitation of Switchover Scope and Additional Recovery" for information on limitation of switchover scopes.

For details on how to edit the mapping definition file, refer to "1. Create the mapping definitions of physical servers [Physical L-Server switchover (physical OS), Physical/Virtual L-Server switchover (VM host/VM guest)]" in "3.6 Creating Files Used for Switchover".

WARNING: VM host resources have not been registered on the destination site.target=
host1,host2...

Description

The VM host resources displayed in "target" do not exist on the switchover destination site.

Corrective Action

When the VM host resource displayed in "target" is not in the scope of switchover, no corrective action is required.

When the VM host resource displayed in "target" is in the scope of switchover, take one of the following corrective actions:

  • Register the VM host displayed in "target" in the server tree on the switchover destination site.

  • Delete the server displayed in "target" from the VM pool definition file on the switchover source site.

  • Delete the definitions of the VM pools that are not switchover targets from the VM pool definition file and add the definitions of the VM pools that are switchover targets.

Refer to "2.4 Limitation of Switchover Scope and Additional Recovery" for information on limitation of switchover scopes.

For details on how to edit the VM pool definition file, refer to "4. Create a VM pool definition file [Virtual L-Server switchover (VM guest)]" in "3.6 Creating Files Used for Switchover".