The events are reported from the following SNMP Traps to a device that supports Fibre Alliance MIB (Fibre Alliance Fibre Channel Management Framework Integration MIB, FA-MIB).
Information
About words of Event display in the table:
The status is replaced with any of "Unknown", "Online", "Offline", "Bypassed", or "Diagnostics".
When the level of an event except event trap is Information, an event display other than "OK" and "Ready" may appear.
Failure Event | Level | Event Display |
---|---|---|
The status of the unit has changed to normal. | Information | The status of the unit has changed to OK/status |
The status of the unit has changed to warning. | Warning | The status of the unit has changed to Warning/status |
The status of the unit has changed to unknown. | Warning | The status of the unit has changed to Unknown/status |
The status of the unit has changed to error. | Error | The status of the unit has changed to FAILED/status |
The status of the power supply, fan, or temperature sensor has changed to normal. | Information | The status of the sensor has changed to OK/status |
The status of the power supply, fan, or temperature sensor has changed to warning. | Warning | The status of the sensor has changed to Warning/status |
The status of the power supply, fan, or temperature sensor has changed to unknown. | Warning | The status of the sensor has changed to Unknown/status |
The status of the power supply, fan, or temperature sensor has changed to error. | Error | The status of the sensor has changed to FAILED/status |
The status of the Fibre Channel port has changed to normal. | Information | The status of the port has changed to Ready/status |
The status of the Fibre Channel port has changed to warning. | Warning | The status of the port has changed to Warning/status |
The status of the Fibre Channel port has changed to unknown. | Warning | The status of the port has changed to Unknown/status |
The status of the Fibre Channel port has changed to error. | Error | The status of the port has changed to FAILURE/status |
Event trap | Error, | The message of the device trap is output as it is. |
When the level is Error or Warning, hardware maintenance is required.
For the event trap, hardware maintenance may also be required when the level is Information. If the contents of the message are unknown, contact your hardware maintenance engineer (CE).
For other events, no action is required when the level is Information.