Failure Event | Level | Event Display | Remarks |
---|---|---|---|
Port failure | Error | FC Port No.number FAULT | *1, *2, *3, and *4 |
Port Online | Information | FC Port No.number Online | |
Port Offline | Information | FC Port No.number Offline | |
Event traps | Error, | The message notified from the device is output as is. |
As for the Ethernet port and FC port number, the Index value output by "show fabric islports" command of Brocade VDX series is displayed.
In the case of the FCoE connection port, a displayed port number is the total value of followings.
Last index value of the Ethernet port displayed by "show fabric islports" command
Port number of FCOE IF output by "show fcoe interface brief" command
For example, when last index value of the Ethernet port is 60 and port number of FCOE IF is 5, a displayed port number is 65.
FCOE IF is displayed with the following format:
Displayed Format | Explanation |
---|---|
XX/YY/ZZ | The explanation of XX, YY, and ZZ is as follows:
|
The Ethernet port is also displayed as "FC Port".
For the Ge port, the following events of "Table 1.1 Trap Common to Devices" are displayed.
In the case of Port Offline: [Link Down Trap]
In the case of Port Online: [Link Up Trap]
The port number is not displayed. Therefore, log in to the target device and check the status of all Ge ports.
When the firmware version is Network OS v3.0.1 or later, the following events of "Table 1.1 Trap Common to Devices" are displayed for all the ports.
In the case of Port Offline: [Link Down Trap]
In the case of Port Online: [Link Up Trap]
The port number is not displayed. Therefore, log in to the target device and check the status of all the ports.