Top
ETERNUS SF Express V16.3 / Storage Cruiser V16.3 Event Guide
FUJITSU Storage

2.1 Windows Server Node

Fujitsu Multipath Disk Control Mechanism Asynchronous Events (SNMP Trap)

Failure Event

Level

Event Display (*1)

Troubleshooting

One path inhibition

Warning

[mpType: 403] "Access path (pPbBtT) fault

Refer to the multipath driver manual and take required actions. Generally, the connection to storage devices and the cable connections must be checked.

[mpType: 1010] "Access path (pPbBtT) fault

Some paths could not be detected at a server node startup. (Multipath operation could not be started.)

Warning

[mpType: 301] "Access path (pPbBtT) could not be detected.

*1: The mpType displays "GRMPD" or "MPHD". The P, B, and T are variables that are displayed e.g. in the form "p2b0t0".

MPIO Asynchronous Events (SNMP Trap)

The events of msdsm (the multi path driver that is built into Windows operating system since Windows Server 2008 by the standard) are reported as MPIO events. When the multi path driver that is compliant to MPIO is used, e.g. Fujitsu ETERNUS multipath driver, these events may be reported.

Failure Event

Level

Event Display

Troubleshooting

Path inhibition

Warning

[MPIO:16] Access path fault.

Path switching has occurred.
Check whether the problem is connection (cable disconnected, switch problem, etc) or in the storage device.

Path switching failed

Warning

[MPIO:32] Fail-over failed.

Path switching has occurred, but it has failed.