Top
PRIMECLUSTER Global Link Services Configuration and AdministrationGuide 4.2Redundant Line Control Function

3.4.2 RIP mode

The following shows the procedure for changing configuration information for RIP mode:

  1. Inactivate the concerned virtual interface using the "stphanet" command. For information, see Section "7.3 stphanet Command".

  2. Stop the monitoring information (only if monitoring is enabled). For information, see Section "7.7 hanetpoll Command".

  3. Change the configuration information.

  4. After changing the configuration information, activate the concerned virtual interface using the "strhanet" command.

  5. Start monitoring (only if monitoring is enabled). For information, see Section "7.7 hanetpoll Command".

The following lists the information that can be changed for RIP mode. No information can be changed besides the information listed below. Delete the concerned definition and add it again.