B.2.3 An error dialog box containing the message "Target executable not found. Could not proceed" appears.

Issue: If a COBOL application is executed or debugged in a workspace created by copying or moving a workspace folder containing the COBOL project, an error dialog box containing the message "Target executable not found. Could not proceed." appears.

Solution: Although the workspace folder containing the COBOL project was copied or moved, the path name used before the copy or move remains defined in Executable file on the "Main" tab of Debug or Run for the COBOL application. This discrepancy causes this message. In this case, click the "Browse" button of Project name on the "Main" tab of Debug or Run, and select the project name again in the Project Selection dialog box. The path name is changed to the correct one.