Top
PRIMECLUSTER  Installation and Administration Guide4.3

D.3 Warning Message

2207  Process (appli) has stopped.

Content:

This message warns that the monitoring target with the process monitoring feature was stopped by other than the correct processing for stopping by the execution of the Offline script.

appli indicates the absolute path name of the monitored process that has been stopped.

Corrective action:

If the process was stopped because of an error, search for the cause by checking the process specification or core file error. The core file is written to the current directory of the process. If the file is written-enabled, the normal access control is applied. The core file is not generated for the process that has an effective user ID different than the actual user ID. For detailed investigations, contact the creator of this process.

5100  An error was detected in the failover unit of the line switching unit. (RCI:addr LSU:mask status:status type:type)

Corrective action:

No corrective action is required because processing is retried. If, however, retries fail repeatedly and if this warning occurs frequently, contact field engineers.

Supplement

An error was detected in the switching control board of the line switching unit.

addr: Indicates the RCI address of the line switching unit in which an error was detected.

mask: Indicates the LSU mask to be controlled.

status: Indicates the an internal status of the line switching unit by error type.

type: Indicates an error type.

  • 3: Indicates that the reserved status was not canceled.

    status: The reserved status of each LSU included in the switching unit is indicated by the value of the LSU mask.

    0: Indicates that the LSU is in the released status.

    1: Indicates that the LSU is in the reserved status.

  • 4: Indicates that the connection has not changed.

    status: The status of the connection of each LSU included in the switching unit is indicated by the LSU mask value.

    0: Indicates that the LSU is connected to port 0.

    1: Indicates that the LSU is connected to port 1.

  • 5: Indicates that the reserved status could not be created.

    status: The reserved status of each LSU included in the switching unit is indicated by the value of the LSU mask.

    0: Indicates that the LSU is in the released status.

    1: Indicates that the LSU is in the reserved status.

LSU mask value

LSU15 LSU14 LSU13 LSU12 ... LSU03 LSU02 LSU01 LSU00

0x8000 0x4000 0x2000 0x1000 ... 0x0008 0x0004 0x0002 0x0001