ETERNUS SF Storage Cruiser V16.2 Operation Guide
FUJITSU Storage

6.1.5 Connectivity Management

With this product, it is possible to manage the storage device's connectivity. It is possible to operate with the same operability without being aware of restrictions according to type of storage device and model.

The target device is selected with the Web Console, and processing is selected from the Action pane.

The executable operations are as follows:

Note

  • The iSCSI-RA port Transfer Rate cannot be changed in the Web Console.
    To change a transfer rate, do it on the ETERNUS Web GUI.

  • Setting the IP address, link local IP address, connection IP address, iSCSI name, or iSCSI alias name of an iSCSI port the same as another iSCSI port may not be allowed.
    Refer to the following table for information on the duplicate registration:

    Storage Model Name

    Duplicate Registration

    IP Address

    Link Local IP Address

    Connection IP Address

    iSCSI Name
    (*1)

    iSCSI Alias Name

    ETERNUS DX S2 series (DX60 S2 excluded)
    ETERNUS DX S3 series
    ETERNUS DX200F

    N/A

    N/A

    N/A

    N/A

    N/A

    ETERNUS DX60/DX60 S2/DX80/DX90
    ETERNUS DX400 series
    ETERNUS DX8000 series

    N/A

    -

    -

    N/A

    N/A

    "A" indicates "Available", and "N/A" indicates "Not Available".

    *1: If the default iSCSI name has been set, it is able to be registered by duplicating.

  • Setting the IP address, iSCSI name, iSCSI alias name, and iSCSI host name of an iSCSI host the same as another iSCSI host may not be allowed.
    Refer to the following table for information on the duplicate registration:

    Storage Model Name

    Duplicate Registration

    IP Address

    iSCSI Name

    iSCSI Alias Name

    iSCSI Host Name

    ETERNUS DX S2 series (DX60 S2 excluded)
    ETERNUS DX S3 series
    ETERNUS DX200F

    A (*1)

    A (*1)

    N/A

    N/A

    ETERNUS DX60/DX60 S2/DX80/DX90
    ETERNUS DX400 series
    ETERNUS DX8000 series

    N/A

    A

    N/A

    N/A

    "A" indicates "Available", and "N/A" indicates "Not Available".

    *1: If both the IP address and the iSCSI name are duplicated, it is not available. If one either is not duplicated, it is available.

  • The function of Multi-VLAN of iSCSI port is not supported.

    On the Web Console, a basic IP address (#0) can be set or viewed. However, expanded virtual IP addresses (#1 through #15) cannot be set or viewed. Set and view the configuration information of expanded virtual IP addresses (#1 through #15) on the ETERNUS Web GUI.