Top
PRIMECLUSTER Wizard for NAS (PRIMEQUEST) 4.3 Configuration and Administration Guide
FUJITSU Software

2.5.4 NAS resource creation (NetApp Filer (cDOT) is used)

  1. When you return to the NAS turnkey wizard, select Netapp.

    Settings of turnkey wizard "NAS"
     1) HELP                              12) Crm:SystemState2(-)
     2) -                                 13) LocalFileSystems(-)
     3) SAVE+EXIT                         14) RemoteFileSystems(-)
     4) -                                 15) IpAddresses(-)
     5) ApplicationName=APP1              16) RawDisks(-)
     6) Machines+Basics(app1)             17) RC-VolumeManagement(-)
     7) CommandLines(-)                   18) VERITAS-VolumeManagement(-)
     8) Controllers(-)                    19) Netapp(-)
     9) Crm:Application(-)                20) Eternusdx(-)
    10) Crm:BasicApplication(-)           21) Gds:Global-Disk-Services(-)
    11) Crm:SystemState3(-)               22) Gls:Global-Link-Services(-)
    Choose the setting to process: 19

  2. When the Netapp wizard is displayed, select AdditionalNetAppFiler.

    Netapp (Netapp_APP1:not yet consistent)
     1) HELP
     2) -
     3) SAVE+EXIT
     4) REMOVE+EXIT
     5) AdditionalNetAppFiler
     6) AdditionalUnlockMachines
     7) (PreOnlineScript=)
     8) (PostOnlineScript=)
     9) (PreOfflineScript=)
    10) (PostOfflineScript=)
    11) (FaultScript=)
    12) NetappClusterFlag=no
    Choose the setting to process: 5

  3. When the following menu is displayed, select FREECHOICE and enter a host name for NAS(for the data access).

    1) HELP
    2) RETURN
    3) FREECHOICE
    Set an additional NetApp Filer: 3
            >> netapp2

  4. When the following menu is displayed, select AdditionalExportpoint. The volume name or qtree is required.

    1) HELP
    2) NO-SAVE+RETURN
    3) -
    4) AdditionalExportpoint
    5) UnLockFlag=always
    6) ExportFlag=no
    7) UnExportFlag=no
    8) ScriptTimeout=300
    9) Mode=7-Mode
    Choose the setting to process: 4

  5. When the following menu is displayed, select FREECHOICE and enter a volume to be exported.

    1) HELP
    2) RETURN
    3) FREECHOICE
    Set an additional export point: 3
            >> /vol/vol2

  6. The following menu is displayed.

     1) HELP
     2) NO-SAVE+RETURN
     3) SAVE+RETURN
     4) AdditionalExportpoint
     5) UnLockFlag=always
     6) ExportFlag=no
     7) UnExportFlag=no
     8) ScriptTimeout=300
    9) Mode=7-Mode 10) Exportpoint[0]=/vol/vol2 Choose the setting to process:

    The following operations are available from the above menu:

    Attributes

    Description

    UnLockFlag

    Select whether or not Unlock processing should be executed on NAS.
    Selecting "always" constantly enables Unlock processing in the event of a Netapp resource failure and a node with the Netapp resource is down.
    Selecting "nodedown" enables Unlock processing only when the node with the Netapp resource is down.
    Default: always (always, nodedown)

    ExportFlag

    Set to "no".

    UnExportFlag

    Set to "no".

    ScriptTimeout

    Specify timeout period (sec) for launching of Online/Offline processing. Normally, you do not need to change the default value.
    Default: 300 (10-31536000)

    Mode

    When NetApp Filer(7-Mode) is used, set to "7-Mode". When NetApp Filer(cDOT) is used, set to "cDOT". You have to set "cDOT ".
    Default: 7-Mode (7-Mode, cDOT)


  7. If addition is complete, select SAVE+RETURN.

    You return to the Netapp Wizard. If you want to add any further NAS device, select AdditionalNetAppFiler.


  8. Internet Protocol address information on a server necessary to unlock is set. The hostname and Internet Protocol address of the cluster server are set. select AdditionalUnlockMachines.

    Netapp (Netapp_APP1:not yet consistent)
     1) HELP
     2) -
     3) SAVE+EXIT
     4) REMOVE+EXIT
     5) AdditionalNetAppFiler
     6) NetAppFiler[0]=netapp2
    7) AdditionalUnlockMachines 8) (PreOnlineScript=) 9) (PostOnlineScript=) 10) (PreOfflineScript=) 11) (PostOfflineScript=) 12) (FaultScript=) 13) NetappClusterFlag=no Choose the setting to process: 7

  9. The cluster server name is selected.

    1) HELP
    2) RETURN
    3) FREECHOICE
    4) node1
    5) node2
    Set an additional UnlockMachine Name: 4

  10. When Internet Protocol address to the hostname is IPv4 address, "Ipv4address=" is selected. When Internet Protocol address to the hostname is IPv6 address, "Ipv6address=" is selected. It is also possible to set both. Procedure 11. and 12., it is a procedure of the IPv4 address.

    1) HELP
    2) NO-SAVE+RETURN
    3) -
    4) Ipv4address=
    5) Ipv6address=
    Choose the setting to process: 4

  11. When the following menu is displayed, select FREECHOICE and enter IPv4 address.

    Setting item : Ipv4address=
    1) HELP
    2) NONE
    3) RETURN
    4) FREECHOICE
    Set an appropriate ipaddress of the unlock machines: 4
            >> 192.168.246.10

  12. When the setting is completed, SAVE+RETURN is selected.

    1) HELP
    2) NO-SAVE+RETURN
    3) SAVE+RETURN
    4) Ipv4address= 192.168.246.10
    5) Ipv6address=
    Choose the setting to process: 3

  13. Internet Protocol address of other node (node2) is set. Repeat the step 8 - 12.

    Netapp (Netapp_APP1:consistent)
     1) HELP
     2) -
     3) SAVE+EXIT
     4) REMOVE+EXIT
     5) AdditionalNetAppFiler
     6) NetAppFiler[0]=netapp2
    7) AdditionalUnlockMachines
    8) UnlockMachinesName[0]=node1 9) UnlockMachinesName[1]=node2 10) (PreOnlineScript=) 11) (PostOnlineScript=) 12) (PreOfflineScript=) 13) (PostOfflineScript=) 14) (FaultScript=) 15) NetappClusterFlag=no Choose the setting to process:

  14. It is set for script files in Netapp resource also start and stop. If it is not necessary, go to next step.

    Netapp (Netapp_APP1:consistent)
     1) HELP
     2) -
     3) SAVE+EXIT
     4) REMOVE+EXIT
     5) AdditionalNetAppFiler
     6) NetAppFiler[0]=netapp2
     7) AdditionalUnlockMachines
     8) UnlockMachinesName[0]=node1
     9) UnlockMachinesName[1]=node2
    10) (PreOnlineScript=)
    11) (PostOnlineScript=)
    12) (PreOfflineScript=)
    13) (PostOfflineScript=)
    14) (FaultScript=)
    15) NetappClusterFlag=no
    Choose the setting to process:  

    Attributes

    Description

    PreOnlineScript

    Executed before Online processing.

    PostOnlineScript

    Executed after Online processing.

    PreOfflineScript

    Executed before Offline processing.

    PostOfflineScript

    Executed after Offline processing.

    FaultScript

    Executed when a fault occurs.


    See

    For further details, see the "PRIMECLUSTER Reliant Monitor Services (RMS) with Wizard Tools Configuration and Administration Guide".


  15. Next, it is set for PRIMECLUSTER to control the NetApp Filer cluster if necessary. In the cluster composition of the NAS device, if network failure between the cluster node and the NAS device is detected PRIMECLUSTER Wizard for NAS can execute failover (storage failover takeover) of the NetApp Filer-Cluster.

    Selects NetappClusterFlag for monitoring the NetApp Filer-Cluster.

    Netapp (Netapp_APP1:consistent)
     1) HELP
     2) -
     3) SAVE+EXIT
     4) REMOVE+EXIT
     5) AdditionalNetAppFiler
     6) NetAppFiler[0]=netapp2
     7) AdditionalUnlockMachines
     8) UnlockMachinesName[0]=node1
     9) UnlockMachinesName[1]=node2
    10) (PreOnlineScript=)
    11) (PostOnlineScript=)
    12) (PreOfflineScript=)
    13) (PostOfflineScript=)
    14) (FaultScript=)
    15) NetappClusterFlag=no
    Choose the setting to process: 15

    Attributes

    Description

    NetappClusterFlag

    It is set for control facility of the NetApp Filer-Cluster.
    Default: no (yes, no)


    Note

    Default is no. Set no to NetappClusterFlag if control facility of the NetApp Filer-Cluster is not necessary, when you use a clustered NAS.


  16. If you use NetApp Filer-Cluster, select yes.

    Setting menu : NetappClusterFlag for Netapp
    1) HELP
    2) RETURN
    3) yes
    4) no
    NetappCluster flag for Netapp: 3

  17. Set parameters.

    Netapp (Netapp_APP1:not yet consistent)
     1) HELP                              12) (PreOfflineScript=)
     2) -                                 13) (PostOfflineScript=)
     3) SAVE+EXIT                         14) (FaultScript=)
     4) REMOVE+EXIT                       15) NetappClusterFlag=yes
     5) AdditionalNetAppFiler             16) NetappClusterDeviceName=
    6) NetAppFiler[0]=netapp2 17) NetappClusterManagementDeviceName= 7) AdditionalUnlockMachines 18) NetappClusterPingCount=10 8) UnlockMachinesName[0]=node1 19) NetappClusterPingTimeout=5 9) UnlockMachinesName[1]=node2 20) NetappClusterPingInterval=5 10) (PreOnlineScript=) 21) NetappClusterPingIPType=IPv4 11) (PostOnlineScript=) Choose the setting to process:

    Attributes

    Description

    NetappClusterDeviceName

    The NAS device name (for the data access) is specified.
    Delimit by ":" and specify two NAS device names.
    example: netapp1:netapp2

    NetappClusterManagementDeviceName

    The NAS device name (for the management) is specified. Delimit by ":" and specify two NAS device names in order of the "NetappClusterDeviceName".
    example: netapp1-MNG:netapp2-MNG

    NetappClusterPingCount

    The execution frequency of the ping command is specified.
    Default: 10 (1 - 60)

    NetappClusterPingTimeout

    The time-out time (sec) for launching of the ping command is specified.
    Default: 5 (1 - 300)

    NetappClusterPingInterval

    The execution interval (sec) of the ping command is specified.
    Default: 5 (1 - 300)

    NetappClusterPingIPType

    The type of IPaddress of the ping / ping6 command to NAS device is specified.

    Default: IPv4 (IPv4, IPv6)


    Note

    • These attributes is set for each userApplication.

    • The NAS device is monitored by the ping / ping6 command. When IPv4 is specified by NetappClusterPingIPType, the ping command is used. When IPv6 is specified by NetappClusterPingIPType, the ping6 command is used. Verify that the access to the NAS device is possible by the type of IPaddress of NetappClusterPingIPType. For details, refer to "2.4 NAS configuration"

    • It is recommended that the value of NetappClusterPingCount, NetappClusterPingTimeout, and NetappClusterPingInterval is default.

    • Do not mix the NAS device name of IPv4 and NAS device name of IPv6 in NetappClusterDeviceName.


    See

    Refer to "Appendix B Turning of the control facility for the NetApp Filer-Cluster" for the parameter of the ping command.


  18. When the setting is completed, SAVE+EXIT is selected.

    Netapp (Netapp_APP1:consistent)
     1) HELP
     2) -
     3) SAVE+EXIT
     4) REMOVE+EXIT
     5) AdditionalNetAppFiler
     6) NetAppFiler[0]=netapp2
     7) AdditionalUnlockMachines
     8) UnlockMachinesName[0]=node1
     9) UnlockMachinesName[1]=node2
    10) (PreOnlineScript=)
    11) (PostOnlineScript=)
    12) (PreOfflineScript=)
    13) (PostOfflineScript=)
    14) (FaultScript=)
    15) NetappClusterFlag=yes
    16) NetappClusterDeviceName=netapp1:netapp2
    17) NetappClusterManagementDeviceName=netapp1-MNG:netapp2-MNG
    18) NetappClusterPingCount=10
    19) NetappClusterPingTimeout=5
    20) NetappClusterPingInterval=5
    21) NetappClusterPingIPType=IPv4
    Choose the setting to process: 3