Top
Systemwalker Desktop Keeper User's Guide for Administrator
FUJITSU Software

7.13.1 Change the Connection Destination (Master) Management Server

This section describes how to change the connection destination (Master) Management Server for the Smart Device Relay Server.

When changing the Smart Device Relay Server from the Management Server change source to the Management Server change destination

  1. Configure the publishing setting for the database (Management Server change destination)

    Follow the procedure in "Configuring the Publishing Settings for the Database (Master Management Server or Management Server)" in "Building a Smart Device Relay Server Environment" in the Systemwalker Desktop Keeper Installation Guide.

  2. On the Smart Device Relay Server, follow the procedure below:

    1. Stop the Smart Device Relay Server

      Use SDSVService.bat (Start/Stop Service of Smart Device Relay Server) to stop the service of the Smart Device Relay Server.

    2. Execute SDSVSetMS.exe (Change Configuration of Smart Device Relay Server)

      Use SDSVSetMS.exe (Change Configuration of Smart Device Relay Server) to change the Systemwalker Desktop Keeper (Master) Management Server IP address and port number registered on the Smart Device Relay Server to the Management Server destination IP address and port number.

    3. Start the Smart Device Relay Server

      Use SDSVService.bat (Start/Stop Service of Smart Device Relay Server) to start the service of the Smart Device Relay Server.

    Refer to "Command Reference" in the Systemwalker Desktop Keeper Reference Manual for details on each command.