This section explains how to perform a new installation of the Smart Device Relay Server of Systemwalker Desktop Keeper.
There are two ways to install the Smart Device Relay Server:
Installation using the wizard
Silent installation
Follow the procedure below to perform installation of the Smart Device Relay Server.
Log on to Windows as a user that belongs to the Administrators group or Domain Admins group. If you are using other applications, close them.
Insert the Systemwalker Desktop Keeper DVD-ROM in the PC - the installer window is displayed.
Select Smart Device Relay Server Installation.
If the installer is not started, start "swsetup.exe" in the DVD-ROM drive.
In the Welcome to the InstallShield Wizard for Systemwalker Desktop Keeper Smart Device Relay Server window, click Next.
The Set installation target folder window is displayed.
To use the installation folder displayed, click Next.
To change the installation folder, click Browse, specify a different folder, and then click Next.
Note
If the installation folder of the Smart Device Relay Server is targeted for compression or encryption, this may impact on program operation. Do not configure compression or encryption settings.
Specify up to 100 halfwidth alphanumeric characters, hyphens (-), or underscores (_) for Installation target folder.
You cannot specify the following drives:
Network drive
Non-NTFS/FAT drive
The path cannot contain commas (,), semicolons (;),number signs (#) or halfwidth kana characters.
Upon successful completion, the Installation is completed window is displayed.
The following message will be displayed. Click Yes to restart the operating system.
Reboot now ?
Note
Silent Installation of the Smart Device Relay Server can only be performed when you are performing installation for the first time.
Installation process must not be interrupted during silent installation.
Follow the procedure below to perform silent installation of the Smart Device Relay Server.
Create an installation parameter CSV file.
If you are performing installation using the default values for all parameters, this step is not required.
Refer to "A.3.1 Installation Parameter CSV File" for details.
Use the parameter setup command to create a response file.
If you did not create an installation parameter CSV file in step 1, this step is not required.
Refer to "A.3.2 Parameter Setup Command" for details.
Use the silent installation script to execute installation.
Refer to "A.3.4 Silent Installation Script" for details.
Check the installation result.
Check the returned value and message from the silent installation script.