Synopsis
f3crheet queuing completion notification
Description
Use this command to issue a queuing completion notification when you want to postpone the shutdown/power off until a specific processing or an application terminates. To do this, you need to define the character string (with the option of this command) in the [Queuing Completion Notification Definition] dialog box beforehand. To use this command in the target host with batch power control system, the definition must be made in the [Queuing Completion Notification Definition] dialog box of the control host. In addition, this command is supported by Windows, Solaris, and Linux versions only.
Option
queuing completion notification
Specify the character string indicating termination of specific processing or an application.
This option can be specified with up to 100 characters. Blank space and comma cannot be included in it.
Do not allow this to be mixed up with character string "queuing completion notification" specified in other processing, applications, and other nodes.
Usage (Performing shutdown after termination of job net)
When executing this command as the job to be activated or terminated at the end of operation, a queuing completion notification is issued when the job net terminates. By defining this queuing completion notification in the [Queuing Completion Notification Definition] dialog box, shutdown processing is postponed until the queuing completion notification specified with this command is issued. Then, power off is performed on the system by the power control function after the shutdown processing has been completed.
This command is set on the shutdown exit of the shutdown job net of the standard Jobscheduler. [Windows]
This command can be useful when you use it also at points other than the shutdown exit of the shutdown job net in Jobscheduler since you can have the system wait events other than job nets simultaneously, and then shut down the system. [Windows]
Return Values
Return value | Meaning |
---|---|
0 | Normal termination |
10 | An error has occurred. Major causes might be the following: - There is an error in parameter setting. - Queuing has already terminated. |
20 | A communication error has occurred between nodes. |
Command Location
Windows | Systemwalker Operation Manager installation directory\mpwalker\bin |
Solaris | /opt/FJSVjmcal/bin |