This section explains messages starting with MpAosfP. These messages are generated by the power control, service/application startup function.
[Description]
Service Systemwalker MpAosfP has started.
[Description]
Service Systemwalker MpAosfP has closed.
[Description]
Service Systemwalker MpAosfP has ended abnormally.
[System Action]
Closes the service. Service/application startup and power control functions are not working.
[System Administrator Response]
Find out the cause of error. If you cannot find corrective measures, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Error has occurred in function.
[Parameter]
ffff : Function name
cccc : Error code
dddd : Error contents
[System Action]
Aborts the process.
[System Administrator Response]
Find out the cause of error from function name, error code, error contents. If you cannot find corrective measures, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Requested re-booting of the system has completed successfully.
[Description]
Requested shut down of the system has completed successfully.
[Parameter]
CCCC: Command name + Parameter
[Description]
Power off request of system is executed properly from Operation Management Client of Systemwalker Centric Manager.
[Parameter]
CCCC : Command name + Parameter
[Description]
Failed to re-boot the system.
[System Action]
Aborts the process.
[System Administrator Response]
Shut down the system and re-start it. Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer if the message occurs frequently.
[Description]
Failed to shut down the system.
[System Action]
Aborts the process.
[System Administrator Response]
Shut down the system. Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer if the message occurs frequently.
[Description]
Failed to power off the system. Power off the system after the shut down process.
[System Action]
Shut down the system. Cannot power off. Auto power on will not be carried out at the time of next power on.
[System Administrator Response]
Power off the system. Power on the system manually at the time of next power on.
Check whether the environment is appropriate by referring to the manual of power control device or that of power control software.
[Description]
Failed to create an environment for queuing the completion event. Queuing is not possible for the completion event.
[Parameter]
iiii : Failed completion event
[System Action]
Cannot carry out queuing process for this completion event.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Completion event has exceeded the maximum value (50).
[System Action]
Ignore the completion event exceeded the maximum value 50.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Failed to open the service database.
[System Action]
Cannot carry out service startup process.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Failed to start the service by using service/application startup function.
[Parameter]
ssss : Service name
[System Action]
Cannot carry out service startup process. Continues with the next process.
[System Administrator Response]
Check the service environment i.e. service name, installation environment.
[Description]
Could not start the service as the previous service is not started by using service / application startup function.
[Parameter]
ssss : Not started service
tttt : Not started earlier service
[System Action]
Cannot carry out service startup process. Continues with the next process.
[System Administrator Response]
Check the service schedule and the environment of the earlier service.
[Description]
It is necessary to define previous service name in service/application startup function.
[Parameter]
ssss : Service name
tttt : Previous service name defined by ssss service
[System Action]
Continue the process by following the specifications of previous service which is not yet started.
[System Administrator Response]
Define the previous service correctly. Delete the definition if not required.
[Description]
Failed to start the application defined by using service/application startup function.
[Parameter]
aaaa : Application name
[System Action]
Application has not started. Continues with the next process.
[System Administrator Response]
Check the application environment.
[Description]
Previous service defined by using service/application startup function does not exist.
[Parameter]
ssss : Service name
[System Action]
Continue the process by following the specifications of previous service which is not yet started.
[System Administrator Response]
Check the earlier service.
[Description]
Service defined by using service/application startup function does not exist.
[Parameter]
ssss : Service name
[System Action]
Service has not started. Continues with the next process.
[System Administrator Response]
Check whether the service name is correct or not. Also check whether the service is installed correctly or not.
[Description]
Failed to execute the command on exit.
[Parameter]
cccc : Command name
[System Action]
Cannot execute the command. Continues with the next process.
[System Administrator Response]
Check the command environment.
[Description]
There was no completion event notification in between the server shut down time and the waiting period even though the monitoring process for completion was carried out.
[Parameter]
iiii : Completion event
[System Action]
Releasing queuing, shut down and power off the server.
[Description]
Could not release the link from user, even though completion monitoring was carried out, as the actual waiting period lapsed from the shut down time of server.
[Parameter]
uuuu : User name
[System Action]
Releasing queuing, shut down and power off the server.
[Description]
Cannot continue the process due to failure in acquiring the dynamic area.
[System Action]
Aborts the process.
[System Administrator Response]
Make necessary provisions in the system or in machine for acquiring the necessary dynamic area.
[Description]
Error in calling the function.
Function name = CreateProcess Error code = 2
Failed to start the application registered to the Application Execution sheet in the Service/Application Execution Pattern Definition dialog box.
Function name = GetServiceKeyName Error code = 1060
Failed to start the service registered to the Service Execution sheet in the Service/Application Execution Pattern Definition dialog box.
[Parameter]
ffff : Function name
cccc : Error code
dddd : Error contents
[System Action]
Continue the process.
[System Administrator Response]
Find out the cause of error from function name, error code and error contents.
Function name = CreateProcess Error code = 2
Check that the path of the application registered to the Application Execution sheet in the Service/Application Execution Pattern Definition dialog box is correct.
Function name = GetServiceKeyName Error code = 1060
Check that the name of the service registered to the Service Execution sheet in the Service/Application Execution Pattern Definition dialog box.
If the cause is still not clear, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Date and time for the next system startup is not entered in the scope which is not supported by the specified power control function. Due to this, next auto power on process cannot be carried out.
[Parameter]
cccc : Number of days from today
dddd : The scheduled date and time
[System Action]
Cannot perform the next auto power on process.
[System Administrator Response]
Perform scheduling on such days on which power control is possible. Or, carry out the manual process at the time of next startup.
Number days on which power control is possible are shown below.
PMAN/L : 45 Days
PowerChutePlus : 14 Days
[Description]
Date and time of next system startup exceeds the number of days on which power control is possible. Due to this, next auto power on process cannot be carried out.
[System Action]
Cannot perform the next auto power on process.
[System Administrator Response]
Perform scheduling on such days on which power control is possible. Or, carry out the manual process at the time of next startup.
Number days on which power control is possible are shown below.
PMAN/L : 45 Days
PowerChutePlus : 14 Days
[Description]
Could not find the power off command of Power Chute Plus (UPSSLEEP.EXE) or PowerChute Business Edition for disconnecting the power supply.
[Parameter]
XXX: Information of specified system path
[System Action]
Cancel the power off process and carry out the shut down process.
[System Administrator Response]
Install UPSSLEEP.EXE. Or, confirm the system path setup of UPSSLEEP.EXE.
An example of system path is shown below:
When the installation directory of UPSSLEEP.EXE is C:\Program Files\PowerChute\upssleep.exe
C:\Program Files\PowerChute
See the OS manual for how to register system path.
[Description]
Could not find the power off command of PMAN/L server power control for disconnecting the power supply.
[Parameter]
XXX: Information of specified system path
[System Action]
Cancel the power off process and carry out the shut down process.
[System Administrator Response]
Confirm the install of PMAN/L and system path setup.
See the OS manual for how to register system path.
[Description]
Could not acquire the dynamic area. Closes Auto Operation Support.
[System Action]
Aborts the process.
[System Administrator Response]
Increase the usable dynamic area by increasing the usable virtual storage and closing the unnecessary applications. After that, start the service (Systemwalker MpAosfP).
[Description]
Error in the environment of Auto Operation Support. Re-install the Auto Operation Support.
[System Action]
Aborts the process.
[System Administrator Response]
Install Systemwalker. If the message keeps appearing even after installation, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Tried to conduct power off process but could not found power stop command (MpStpSV.EXE) of power control software corresponding to Systemwalker.
[Parameter]
XXX: Information of specified system path
[System Action]
Stop the power off process and shut down.
[System Administrator Response]
Install MpStpSV.EXE or confirm the settings of system path of MpStpSV.EXE. See the power control software manual and OS manual for installation of MpStpSv.EXE and confirmation and setup of system path respectively.
[Description]
SMTP server host name of E-mail send destination is not specified.
[System Action]
Cannot send mail. Continues with the next process.
[System Administrator Response]
Check the SMTP server host name of the E-mail send destination.
[Description]
Error in user name process of pop-up messages.
[System Action]
Does not carry out pop-up message notification. Continues with the next process.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Error has occurred while sending pop-up messages. There are chances that the specified user or the computer may not exist or the Messenger service is not started.
[System Action]
Continues the process.
[System Administrator Response]
Confirm whether the Messenger service has started or not. Also confirm the specified user or computer name.
[Description]
Error in sending pop-up messages.
[System Action]
Continue the process.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Domain specified at the time of sending pop-up message does not exist. Unable to find the server in domain.
[System Action]
Does not carry out pop-up message notification. Continues with the next process.
[System Administrator Response]
Confirm whether the specified domain is correct or not.
[Description]
Systemwalker Centric Manager is not installed. Notification by e-mail or pop-up message will not be performed.
[System Action]
Cannot perform completion notification. Continues with the next process.
[System Administrator Response]
Install Systemwalker Centric Manager.
[Description]
[Windows version]
Systemwalker MpAosfB service is not started or failed in communication with Systemwalker MpAosfB service.
[UNIX version]
Systemwalker Centric Manager is not started or failed in communication with Systemwalker Centric Manager.
Due to this, notification by e-mail or pop-up message will not be performed.
[System Action]
Cannot perform completion notification. Continues with the next process.
[System Administrator Response]
[Windows version]
Start Systemwalker MpAosfB service. If the action execution destination is set to another server on Centric Manager, check that there is no problem in the communication environment with the server specified as the destination.
[UNIX version]
Start Systemwalker Centric Manager. Check that there is no problem in the communication environment with the server specified as the action execution destination on Centric Manager.
[Description]
Could not request to send E-Mail due to insufficient memory.
[System Action]
Cannot send mail. Continues with the next process.
[System Administrator's Response]
Increase the memory. Close the unnecessary applications and increase the usable memory.
[Description]
Failed to power off the managed host from the managing host with the batch power control function. The cause of this failure would be as follows:
Wrong managed host name
The managed host is not running
Calendar service is not running on the managed host
Error occurred in communication environment
[Parameters]
hhhh: Name of the managed host of which power off has failed.
[System Action]
Ignores failure in power off of the managed host and Continues with the process.
[System Administrator Response]
Check whether the managed host is running and power control service is operating. After identifying and resolving the cause of the failure, power off the managed host.
[Description]
Target host name for on/off is not specified in power on/off of remote server.
[System Action]
Aborts the process.
[System Administrator Response]
Specify the correct host name.
[Description]
The name of the target host for server power on/off specified on the remote server exceeds 256 bytes.
[System Action]
Aborts the process.
[System Administrator Response]
Specify the correct host name.
[Description]
Error has occurred in the parameter of PMAN/L power control API. The error is in power on/off of remote server.
[System Action]
Aborts the process.
[System Administrator Response]
Check the host name. If you cannot find the cause, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
There is improper execution environment of PMAN/L power control in power on/off of remote server.
[System Action]
Aborts the process.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Error has occurred in power on/off of remote server while transmitting the requested PMAN/L power control.
[System Action]
Aborts the process.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Error in the schedule setup of PMAN/L power control.
[System Action]
Aborts the process.
[System Administrator Response]
Check PMAN/L setup.
[Description]
Cannot power on/off as it is not allowed.
[System Action]
Aborts the process.
[System Administrator Response]
Confirm the status/environment of the server on which power on/off process is carried out. If you cannot find the cause, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Power control box key is in "OPERATE" mode.
[System Action]
Aborts the process.
[System Administrator Response]
Make the mode of power control box key as "LOOK".
[Description]
Power control is not possible as the power on server is failed.
[System Action]
Aborts the process.
[User Response]
Reserve available space if there is not enough available space in the file system.
[System Administrator Response]
Reserve available space if there is not enough available space in the file system.
If the problem persists even after reserving the space, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Server specified is already switched off or is in power off status.
[System Action]
Aborts the requested power off process. Continues power off process to the server which is in the middle of the process.
[Description]
Parameter of the command is not specified.
[System Action]
Aborts the process.
[System Administrator Response]
Re-execute by specifying the parameter.
[Description]
Failed to open socket.
[System Action]
Aborts the process.
[System Administrator Response]
Check TCP/IP environment of the system. If you cannot find the cause of error, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Error has occurred while getting the self host name.
[System Action]
Aborts the process.
[System Administrator Response]
Check TCP/IP environment of the system. If you cannot find the cause of error, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Cannot decide the proper host name for remote power control.
[System Action]
Aborts the process.
[System Administrator Response]
Check the host name. If you cannot find the cause of error, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Internal operation error has occurred in the power control process.
[System Action]
Aborts the process.
[System Administrator Response]
Collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
Transmission error has occurred in the power control process.
[System Action]
Aborts the process.
[System Administrator Response]
Check TCP/IP environment of the system. Confirm SNMP adapter environment of send destination. If you cannot find the cause of error, collect data of power control_calendar with the Maintenance Information Collection Tool and contact a Fujitsu's system engineer.
[Description]
DLL (F3DMIF32.DLL) useful for PMAN/L control does not exist.
[System Action]
Power control function is not working. Carries out the shut down process.
[System Administrator Response]