Top
Systemwalker Operation Manager Q & A Guide
FUJITSU Software

1.7 Q: What Are the Type, Size (or Retention Period), and Generations Held for each Log File Output by Systemwalker Operation Manager?

Applicable versions and levels

A

Jobscheduler log file

Log type

Contains the job net and job execution history (start time, end time, and completion code).

Log storage location

jobdb1.log/jobdb2.log/jobdb3.log file in the database directory for Jobscheduler

Log file size or retention period (*1)

1 to 99 MB (default: 3 MB)
However, for V5.2 and V5.0L30 or earlier versions, the range is 1 to 9 MB.

Number of files for cyclic use

3 (jobdb1.log, jobdb2.log, and jobdb3.log)
This number cannot be changed.

*1: You can set this value by opening the Define Jobscheduler Startup Parameters window, clicking the Database tab, and then selecting a value for Log file size.

Job execution history information log [V5.1 and V5.0L10 or later]

Log type

Contains the date and time at which each job was submitted, started, completed, and deleted, and the completion code of the job.
The log files contain binary attributes, so they cannot be referenced directly. Use the mjsview command to reference the log files.

Log storage location (*1)

By default, this log is stored under the following directory:

[Windows versions]
<Systemwalker Operation Manager installation directory>\MpWalker.JM\mpmjessv\hist

[UNIX versions]
/var/spool/mjes/hist

Log file size or retention period (*1)

1 to 31 days (default: 7 days)

Number of files for cyclic use

Files older than the specified number of days are deleted.

*1: You can set this value by opening the Define Operating Information window, clicking the Logging tab, and then selecting a retention value.

Operation record information log (if set in Operation information in the Environment definition window of Systemwalker Operation Manager)

Log type

Operation information for executed jobs and job nets is stored in CSV format.

Log storage location (*1)

No default

Log file size or retention period (*1)

1 to 31 days

Number of files for cyclic use

Files older than the specified number of days are deleted.

*1: You can set this value by opening the Define Operating Information window, clicking the Logging tab, and then selecting a retention value.