8.5.2 "0xb007(0x410e): The Task Link Engine process startup request was not accepted." is Displayed

Error message

0xb007(0x410e): The Task Link Engine process startup request was not accepted.

Applicable versions and levels

Action 1

Points to check

Has the client Task Link engine started in the client specified in the first parameter of the client Task Link command?

Cause

The client Task Link engine has not started in the client.

Action method

Start the client Task Link engine in the Systemwalker Operation Manager client, by selecting Start (or Apps) >> Systemwalker Operation Manager and selecting Client Task Link.

Note that, by configuring the settings described in "Definition for Task Link with Clients" of the Installation Guide, the client Task Link engine (cnscleng.exe) can be made to start automatically when the Windows login is performed.

Action 2

Points to check

Can the host name specified in the first parameter of the client Task Link command be resolved correctly to the IP address?

Whether the host name could be resolved to the IP address or not can be confirmed by specifying the host name in the ping command.

Example: ping hostname

In the example above, hostname is the host name specified in the parameter of the client Task Link command.

Cause

The host name cannot be resolved to the IP address.

Action method

Perform one of the following procedures: