Top
Systemwalker Operation Manager Troubleshooting Guide
FUJITSU Software

8.2.1 When the Client Application Startup is Executed by the execacli Command, "0x13A" is Returned

Applicable versions and levels

Action

Points to check

Was the application started on the client by the execacli command canceled?W

Cause

The error code "0x13A" is returned when a client application is canceled. Application started on the client may have been canceled.

Action method

Do not cancel applications started on the client using the execacli command.

Refer to the following manual:

Information

Closing the application window can cause unintended cancelation by the user of an application started on the client.

By specifying the /AM:ICON parameter in the execacli command, the application started on the client will be activated in iconic state, therefore the risk of closing the window by mistake is reduced.