Top
Systemwalker Operation Manager Troubleshooting Guide
FUJITSU Software

7.5.1 Cannot Start the Monitored Log File Setup Window

Error message

Failed to start the process.

\bin\mpopfmon.exe The system cannot find the path specified.(3)

Applicable versions and levels

Action

Points to check

Was a server on which only Systemwalker Operation Manager is installed connected to a server on which Systemwalker Operation Manager and Systemwalker Centric Manager coexist?

Cause

In the mixed environment for Systemwalker Ioeration Manager and Syetmwalker Centric Manager (as well as Syetemwalker Event Agent for auto function), it will be run as Systemwalker Centric Maneger. For this reason, if the connection destination is a mixed environment, the Systemwalker Centric Manager client is required, and not the Systemwalker Operation Manager client.

Action method

Install Systemwalker Centric Manager on the connection source server.