4.14.6 The Error Message "Failure in accessing project DB." is Output [Windows Versions]

Error message

Failure in accessing project DB.

Applicable versions and levels

Action

Points to check

Is another application (virus check software or backup software) that can access the Jobscheduler database directory running?

Cause

If an application accessed the Jobscheduler database directory while Jobscheduler is accessing the same directory, it may corrupt the job net definition file in the database directory and display the error message in the title.

Action method

Execute the mprso command to restore the backed up definition information. Note that the definition information is reverted to the point when the backup is taken.

While Jobscheduler is running, refrain from accessing the files in the Jobscheduler database directory.

Refer to the following manuals for information on the cautions required when using the backup software and virus check software: