Top
Symfoware Server V12.1.0 Cluster Operation Guide
FUJITSU Software

9.7.4 Uninstalling in Database Multiplexing Mode

This section explains how to uninstall Symfoware Server on a server using database multiplexing mode.

You must delete the Mirroring Controller settings from both the primary server and standby server before uninstalling Symfoware Server.

  1. Stop the multiplexed instances and Mirroring Controller

    Refer to "9.1 Starting and Stopping Instances" for information on how to stop the instance.

  2. Unregister Mirroring Controller from the Windows service

    Execute the mc_ctl command in unregister mode to unregister Mirroring Controller from the Windows service.

    Example)
    > mc_ctl unregister -M D:\mcdir\inst1
  3. Delete registries related to the event log

    If messages are output to the event log, DLLs are registered in accordance with "8.2.2 Preparatory Tasks for the Output of Error Logs to the Event Log". Delete these registries so that no unnecessary issues occur.

    Example)
    The following is an example in which the DLL of a 64-bit product that is registered under the default event source name is deleted.
    > regsvr32 /u "c:\Program Files\Fujitsu\symfoserver64\lib\mcevent.dll"
    • Delete the registered DLL for each instance

      DLL registration is performed so that messages output to the event log are identified by each instance, and are output to any event source named by the user.

      Accordingly, it is necessary to delete the DLL registry for each instance. Delete the DLL registry for each event source name.

      Example)
      The following is an example in which the DLL of a 64-bit product that is registered under the event source name "Mirroring Controller inst1" is deleted.
      > regsvr32 /u /i:"Mirroring Controller inst1" "c:\Program Files\Fujitsu\symfoserver64\lib\mcevent.dll"
    • If installing multiple versions

      If the database multiplexing system you set up using the Symfoware Server package has been set to output error logs to the event log, use the DLL path name that you took note of previously as explained in "8.2.2 Preparatory Tasks for the Output of Error Logs to the Event Log" to reregister the default event source name.

    Note

    Ensure that you delete the DLLs before the uninstallation. If you perform the uninstallation without doing so, you may not be able to delete the DLLs at a later time.

  4. Uninstall Symfoware Server

    Refer to "Uninstallation" in the Installation and Setup Guide for Server for information on how to uninstall Symfoware Server.