Top
ETERNUS SF Storage Cruiser V16.1 Operation Guide
FUJITSU Storage

3.1.1 Network Requirements

Communication with Manager

When a firewall is placed between Manager and a managed device, set the following port numbers to be able to pass the firewall.

Transmission Destination Device

Port/Protocol

Transmission Start Direction

Function

Server node (Agent)

4917/tcp

Manager -> device

Configuration management,
Polling monitoring

162/udp

Device -> Manager

Fault management

Windows Server 2008 R2 (Hyper-V function installation environment)
Windows Server 2012 (Hyper-V function installation environment)

5985/tcp

Manager -> device

Configuration management

VMware vSphere 4 or later
VMware vCenter Server 4 or later

443/tcp

Manager -> device

Configuration management,
Polling monitoring

Fibre Channel switches of Fabric OS V6.2 or earlier as follows:

ETERNUS SN200 series
Brocade Fibre Channel switch
PRIMERGY Fibre Channel switch blade

161/udp

Manager -> device

Configuration management,
Performance management,
Polling monitoring

23/tcp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

Fibre Channel switches of Fabric OS V6.3 or later as follows:

ETERNUS SN200 series
Brocade Fibre Channel switch
PRIMERGY Fibre Channel switch blade

161/udp

Manager -> device

Configuration management,
Performance management,
Polling monitoring

22/tcp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

Brocade VDX series
PRIMERGY BX Ethernet Fabric Switch

161/udp

Manager -> device

Configuration management,
Performance management,
Polling monitoring

830/tcp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

ETERNUS DX80 S2/DX90 S2
ETERNUS DX100 S3/DX200 S3
ETERNUS DX400 S2 series
ETERNUS DX500 S3/DX600 S3
ETDRNUS DX8000 S2 series

161/udp

Manager -> device

Configuration management,
Performance management,
Polling monitoring

22/tcp

Manager -> device

Configuration management,
Performance management

1999/tcp
(*1)

Manager -> device

Configuration management

1372/tcp
(*2)

Manager -> device

Configuration management,
Performance management

162/udp

Device -> Manager

Fault management

ETERNUS DX60/DX60 S2/DX80/DX90
ETERNUS DX400 series
ETERNUS DX8000 series

161/udp

Manager -> device

Configuration management,
Performance management,
Polling monitoring

1999/tcp
(*1)

Manager -> device

Configuration management

23/tcp

Manager -> device

Configuration management
(For ETERNUS DX60/DX60 S2/DX80/DX90)

162/udp

Device -> Manager

Fault management

Disk Storage System other than listed above

161/udp

Manager -> device

Configuration management,
Polling monitoring

80/tcp

Manager -> device

Configuration management

1999/tcp
(*1)

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

ETERNUS LY250/LT270

161/udp

Manager -> device

Configuration management

162/udp

Device -> Manager

Fault management

ping/icmp

Manager -> device

Polling monitoring

NetApp FAS Series and V-Series

162/udp

Device -> Manager

Fault management

161/udp

Manager -> device

Polling monitoring

Manual embedding, and others

162/udp

Device -> Manager

Fault management

ping/icmp

Manager -> device

Polling monitoring

*1: For Maintenance connection
*2: For Maintenance-Secure connection

Communication with Agent

To place Storage Cluster Controller, if a firewall is placed between Agent and a managed device, set the following port number to be able to pass the firewall.

Transmission Destination Device

Port/Protocol

Transmission Start Direction

Function

ETERNUS DX100 S3/DX200 S3
ETERNUS DX500 S3/DX600 S3

1372/tcp (*1)

Agent -> device

Monitoring by Storage Cluster Controller

*1: For Maintenance-Secure connection