Top
ETERNUS SF Express V16.1 / Storage Cruiser V16.1 / AdvancedCopy Manager V16.1 Web Console Guide
FUJITSU Storage

6.3.5 Reload Tape Library Configuration Information

The procedure to reload the tape library configuration information is as follows:

  1. On the global navigation tab, click Storage.

  2. On the Category pane, click Tape Library.
    The registered tape libraries are displayed on the Main pane.

  3. On the Main pane, check the target tape library checkbox.

  4. On the Action pane, click Reload Conf. under Tape Library.

Point

If any of the situations below have occurred, perform the above-described operation to display the up-to-date information.

  • Changed the tape library configuration.

  • Check the status of the constituted elements because of trouble in the tape library.

  • Clear the Error status after the recovery because of trouble in the tape library.

Note

The reloading of tape library configuration information may take from a few minutes to over 10 minutes depending on the device configuration. The Job Status pane allows you to confirm the completion of tape library configuration information reloading. However, since the information in the Job Status pane is automatically deleted 24 hours after processing is completed, check deleted information in "11.1 Display Operation History". The tape library configuration information reloading has completed when the displayed items of the Operation History screen is as follows:

  • Action: Reload Configuration on Tape Library

  • State: Complete

  • Result: Success

  • Target: Name of the registered tape library

Please do not perform any operation for this tape library until the configuration information reloading has been completed.