Top
ETERNUS SF Express V16.1 / Storage Cruiser V16.1 / AdvancedCopy Manager V16.1 Web Console Guide
FUJITSU Storage

3.1 Update of Information (Refresh Screen)

The information displayed on the screen is updated automatically at intervals (Default is 30 seconds) set to Screen Refresh Interval. The input item in the screen is held before and after the update.

According to the setting of Target of the screen refresh preference, the area updated automatically is different as shown in the following tables.

Object to Be Updated

Explanation

Entire

Automatic refresh is active for the whole area (Menu area, Category pane, Main pane, Action pane, and Job Status pane) of the screen.

However, when it meets any following requirements, the Category pane, the Main pane, and the Action pane are not updated automatically.

  • The screen for setting or the Map View screen is displayed.

  • A dialog box is displayed.

Menu area and Job Status pane

Automatic refresh is active for the menu area and Job Status pane only.

None (Disabled)

Automatic refresh is inactive.

The screen can be updated manually by clicking in the menu area.

Information

Note

  • The automatic refresh never operates on the screen before log in and the screen displayed by another window.

    • Login screen

    • Session Timeout screen

    • Logical Path View

    • End to End View detail screen

    • Performance Chart window

  • The automatic refresh never operates for the information related to Automated Storage Tiering.

  • Clicking resets the following setting values in the Main pane to the default value. Refer to "2.3 Main Pane" for respective setting.

    • Filter setting

    • Page setting

    • Displayed records setting

    In addition, when information screen has tabs, clicking displays the leftmost tab information on the Main pane regardless of the current tab.

  • Clicking does not reset values in the Filter Setting on the Job Status pane.

  • Clicking displays the existing information held by ETERNUS SF system. It does not acquire updated information from the devices. Clicking Reload Conf. or Refresh in an Action pane obtains updated information from the device.
    Device information excluding system information, device configuration status, performance management configuration information and the information related to Automated Storage Tiering is automatically collected for the following devices. Clicking displays the automatically collected information.

    • ETERNUS DX80 S2/DX90 S2 (firmware version V10L40 or later)

    • ETERNUS DX100 S3/DX200 S3 (all firmware versions)

    • ETERNUS DX400 S2 series (all firmware versions)

    • ETERNUS DX500 S3/DX600 S3 (all firmware versions)

    • ETERNUS DX8000 S2 series (firmware version V10L40 or later)