Top
ETERNUS SF Express V16.0/ Storage Cruiser V16.0/ AdvancedCopy Manager V16.0 Messages
FUJITSU Storage

Chapter 11 Messages of FJSVrcx Prefix

FJSVrcx:INFO:27700:command:primary node setup completed

Explanation

The cluster setup on the primary node ended normally.

System Administrator Corrective Action

Proceed to the next operation according to the cluster environment configuration procedure.

FJSVrcx:INFO:27701:command:secondary node setup completed

Explanation

The cluster setup on the secondary node ended normally.

System Administrator Corrective Action

Proceed to the next operation according to the cluster environment configuration procedure.

FJSVrcx:INFO:27702:command:primary node deletion completed

Explanation

The cluster deletion on the primary node ended normally.

System Administrator Corrective Action

Proceed to the next operation according to the cluster environment configuration procedure.

FJSVrcx:INFO:27703:command:secondary node deletion completed

Explanation

The cluster deletion on the secondary node ended normally.

System Administrator Corrective Action

Proceed to the next operation according to the cluster environment configuration procedure.

FJSVrcx:INFO:27733:command:canceled

Explanation

The command was cancelled.

System Administrator Corrective Action

No action is required.

FJSVrcx:INFO:27751:command:cluster deletion (erase shared disk data) completed

Explanation

The shared disk data deletion was completed.

System Administrator Corrective Action

If any node where the cluster environment is not deleted exists, delete the cluster environment in force mode (using -f when executing rcx_clunsetup). After the deletion is completed, uninstall the Manager.

FJSVrcx:INFO:27753:command:cluster deletion (force mode) completed

Explanation

The cluster unsetup in force mode was completed.

System Administrator Corrective Action

Uninstall the Manager.

FJSVrcx:WARNING:47752:command:cluster deletion (force mode) completed excluding erase shared disk data

Explanation

Except for shared disk data deletion, the cluster unsetup in force mode was completed.

System Administrator Corrective Action

Check that the shared disk is accessible then delete shared disk data (using rcx_clunsetup with -e MountPoint).

FJSVrcx:ERROR:67101:command:not privileged

Explanation

The command was executed without OS administrator authority.

System Administrator Corrective Action

Execute using OS administrator authority.

FJSVrcx:ERROR:67102:command:option:illegal option

Explanation

The option is invalid, usage is displayed.

System Administrator Corrective Action

Check the command, and execute it again.

FJSVrcx:ERROR:67117:command:obj:failed to create file or directory

Explanation

The obj file or directory cannot be created.

System Administrator Corrective Action

Check the following, remove the cause of the problem, and execute the command again.

  • Check the directory permission.

  • Check that there is enough disk area available.

FJSVrcx:ERROR:67126:command:obj:No such directory

Explanation

The directory specified was not found.

System Administrator Corrective Action

Specify the correct directory.

FJSVrcx:ERROR:67129:command:syntax error

Explanation

A command syntax error has occurred. The usage is displayed.

System Administrator Corrective Action

Check the command, and execute it again.

FJSVrcx:ERROR:67130:command:option:option requires an argument

Explanation

An argument was not specified for the option. The usage is displayed.

System Administrator Corrective Action

Check the command, and execute it again.

FJSVrcx:ERROR:67704:command:option:secondary node deletion completed

Explanation

The option is incorrect. The usage will be output.

System Administrator Corrective Action

Check the command, and re-execute the command.

FJSVrcx:ERROR:67706:command:ipAddress:invalid IP address format

Explanation

The IP address format is incorrect.

System Administrator Corrective Action

Check the IP address.

FJSVrcx:ERROR:67707:command:setup command already running

Explanation

The cluster setup command or the cluster unsetup command is already active.

System Administrator Corrective Action

Check whether the cluster setup command or the cluster unsetup command is running somewhere else.

FJSVrcx:ERROR:67709:command:not privileged

Explanation

The command was activated by a user other than the OS administrator (root).

System Administrator Corrective Action

Execute the command as the OS administrator (root).

FJSVrcx:ERROR:67710:command:mountPoint:not mounted

Explanation

The shared disk has not been mounted on mount point mountPoint.

System Administrator Corrective Action

Check the mount status of the shared disk for Management Server shared data.
When "/" was added in the end of the mount point mountPoint, delete the "/" then re-execute.

FJSVrcx:ERROR:67711:command:software:not installed

Explanation

Cluster software software has not been installed.

System Administrator Corrective Action

Check whether the cluster setup command or the cluster unsetup command is running.

FJSVrcx:ERROR:67714:command:nodeType: cluster setup already completed in this node

Explanation

The cluster environment of node type nodeType has been configured on the current node.

System Administrator Corrective Action

Check the cluster environment status on the current node.

FJSVrcx:ERROR:67715:command:cluster setup already completed in another node

Explanation

The cluster environment of the node type specified with the cluster setup command has been configured on another node.

System Administrator Corrective Action

Check whether the node type specified with the executed command is correct.
Check whether the cluster environment of the node type specified with the executed command has already been configured on another node.

FJSVrcx:ERROR:67716:command:primary node setup not completed

Explanation

The cluster environment has not been configured on the primary node.

System Administrator Corrective Action

Check whether the shared disk for mounted Management Server shared data is correct.
Configure the cluster environment on the primary node.

FJSVrcx:ERROR:67717:command:switch:parameter:parameter conflict

Explanation

Data different from the previous one was specified.

System Administrator Corrective Action

Check the argument values of the command.

FJSVrcx:ERROR:67725:command:option:illegal option

Explanation

The option is incorrect. The usage will be output.

System Administrator Corrective Action

Check the command options, and re-execute the command.

FJSVrcx:ERROR:67726:command:secondary node not deleted

Explanation

The cluster environment on the secondary node is not deleted.

System Administrator Corrective Action

Check whether the shared disk for mounted Management Server shared data is correct.
Delete the cluster environment on the secondary node, and execute the command again.

FJSVrcx:ERROR:67727:command:no cluster setup node

Explanation

The cluster environment has not been configured.

System Administrator Corrective Action

Check whether the Management Server cluster environment has been configured.

FJSVrcx:ERROR:67740:command:cluster setup failed (setup data invalid)

Explanation

The cluster setup failed. The cluster environment configurations are invalid.

System Administrator Corrective Action

Delete the cluster environment in force mode, and uninstall the Manager.

FJSVrcx:ERROR:67741:command:setup command not installed

Explanation

The module for cluster setup has not been installed.

System Administrator Corrective Action

Check whether Manager installation is valid.

FJSVrcx:ERROR:67742:command:file:setup data inconsistency

Explanation

Inconsistency was found in the cluster environment configurations.

System Administrator Corrective Action

Collect the following files and contact Fujitsu Technical Support.

  • Files output to file

  • For Manager, all files under /opt/FJSVrcxmr/cluster/env directory

FJSVrcx:ERROR:67743:command:setup data invalid

Explanation

The cluster environment configurations are invalid.

System Administrator Corrective Action

Delete the cluster environment in force mode (using -f when executing rcx_clunsetup). After the deletion is completed, uninstall the Manager.

FJSVrcx:ERROR:67744:command:shared disk data invalid

Explanation

Data on the shared disk is invalid.

System Administrator Corrective Action

Delete the cluster environment in force mode (using -f when executing rcx_clunsetup). After the deletion is completed, uninstall the Manager.

FJSVrcx:ERROR:67745:command:property:manager:value:setup data conflict

Explanation

Property value property of the cluster setup command does not match configuration value value on Management Server manager for which cluster setup is done.

System Administrator Corrective Action

Specify the same configuration value to perform setup.

FJSVrcx:ERROR:67747:command:cluster setup failed

Explanation

The cluster setup failed.

System Administrator Corrective Action

Check the execution environment then re-execute the command. If the situation is not improved, contact Fujitsu Technical Support.

FJSVrcx:ERROR:67748:command: can not execute in normal cluster setup node

Explanation

The cluster setup is in normal condition. The unsetup command cannot be executed specifying shared disk data deletion.

System Administrator Corrective Action

Shared disk data deletion (using -e MountPoint when specifying rcx_clunsetup) cannot be performed.
Delete the cluster environment following the procedure given in "Deleting the Management Server Cluster Environment" in the ETERNUS SF Cluster Environment Setup Guide.

FJSVrcx:ERROR:67749:command:cluster deletion failed

Explanation

The cluster unsetup failed.

System Administrator Corrective Action

Delete the cluster environment in force mode (using -f when executing rcx_clunsetup). After the deletion is completed, uninstall the Manager.

FJSVrcx:ERROR:67750:command:cluster deletion (erase shared disk data) failed

Explanation

The shared disk data deletion failed.

System Administrator Corrective Action

Check the execution environment then re-execute the command. If the situation is not improved, contact Fujitsu Technical Support.

FJSVrcx:ERROR:67899:command:internal error

Explanation

Internal error occurred.

System Administrator Corrective Action

Refer to "Collecting the troubleshooting information" in the ETERNUS SF Storage Cruiser Operation Guide to collect the information required for troubleshooting and contact Fujitsu Technical Support.

FJSVrcx:ERROR:67999:command:internal error, details.

Explanation

An internal error occurred during execution of the command.

System Administrator Corrective Action

Refer to "Collecting the troubleshooting information" in the ETERNUS SF Storage Cruiser Operation Guide to collect the information required for troubleshooting and contact Fujitsu Technical Support.