Top
PRIMECLUSTER  Installation and Administration Guide 4.3

D.1 Searching for a Message

This section explains the procedure for searching for a message reference.

The PRIMECLUSTER display formats are classified into five types. Determine the reference according to the format of the displayed message.

Display format 1

FJSVcluster:severity:program:message-number:message 
severity:

Indicates the message severity level.

There are five message severity levels. Stop (HALT), Information (INFO), Warning (WARNING), Error (ERROR), and Question (QUESTION).

program:

Indicates the name of the program that outputs this message.

message-number:

Indicates the message number.

message:

Indicates the message text.

Search procedure

After confirming the severity and message-number, determine the reference by referring to the table below.

severity

message-number

Reference

Stop (HALT)

0100, 0101

CF Configuration and Administration Guide

11.10.2.1 HALT Messages

Information (INFO)

2620, 2621, 2622, 2700, 2701

D.2 Information Messages

2100, 2200, 2201, 2202, 2203, 2204, 2205, 3200, 3201, 3202, 3203, 3204, 3205, 3206

CF Configuration and Administration Guide

11.10.2.2 INFORMATION messages

3080, 3081, 3082, 3083, 3084, 3085

CF Configuration and Administration Guide

11.13.1 INFORMATION messages

Warning (WARNING)

4250, 5021, 5200

CF Configuration and Administration Guide

11.10.2.3 WARNING messages

Error (ERROR)

6000, 6001, 6002, 6003, 6004, 6007, 6009, 6208, 6615, 6616, 6617, 6618, 6619, 6621, 6623, 6624, 6651, 6680, 6750, 6751, 6752, 6753, 6754, 6755, 6817

D.3 Error Messages

6000-6001, 6003-6010, 6021, 6025

6200-6204, 6206-6218, 6300,6600-6604, 6606-6608, 6611, 6614-6616, 6653, 6900-6904

7500-7522, 7535-7543, 7545-7546

CF Configuration and Administration Guide

11.13.3 ERROR message

Question (QUESTION)

1421, 1422, 1423

D.4 Operator Intervention Messages

Display format 2

command-name:message
command-name:

Indicates the command name.

message:

Indicates the message (describing the phenomenon, message number, reason, etc.).

Search procedure

Messages of display format 2 are described in the PRIMECLUSTER Cluster Foundation (CF) Configuration and Administration Guide. Confirm command-name, and then determine the reference by referring to the following table:

Function

command-name

Reference in the CF Configuration and Administration Guide

Cluster node configuration

cfconfig

11.1 cfconfig message

CIP2.0 start/stop

cipconfig

11.2 cipconfig message

Outputting the node communication state

cftool

11.3 cftool message

Outputting and manipulating quorum information

rcqconfig

11.4 rcqconfig message

rcqquery

11.5 rcqquery message

CF execution

CF

11.6 CF runtime messages

Display format 3

(SMAWsf,number1,number2):message
number1,number2:

Indicates the message number.

message:

Indicates the message.

Search procedure

Messages of display format 3 are described in PRIMECLUSTER Cluster Foundation (CF) Configuration and Administration Guide.

Confirm number1 and number2, and then determine the reference by referring to the table below.

Operation

(number1-number2)

Reference location in CF Configuration and Administration Guide

Shutdown facility

(10, 2)-(10, 12)

(10, 15)-(10, 17), (10, 19), (10, 20)

(10, 23), (10, 101)

(30, 2)-(30, 10), (30, 12)-(30, 17)

(50, 3)-(50, 4), (50, 6), (50, 9)

11.11 Shutdown Facility

Display format 4

(err-code,message-number):message
err-code:

Indicates the error code.

message-number:

Indicates the message number.

message:

Indicates the message.

Search procedure

Messages of display format 4 are described in the "PRIMECLUSTER Reliant Monitor Services (RMS) Reference Guide." Confirm err-code and message-number, and then determine the reference by referring to the table below.

Operation/state

err-code

message-number

Reference location in RMS Troubleshooting Guide

switchlog

ADC

1, 2, 3, 4, 5, 15, 17, 18, 20, 25, 27, 30, 31, 32, 33, 34, 35, 37, 38, 39, 41, 43, 44, 45, 46, 47, 48, 49, 57, 58, 59, 60, 61, 62, 63

5 Non-fatal error messages

ADM

55, 57, 58, 59, 60, 62, 63, 67, 70, 95, 96

BM

8, 14, 52, 54, 68

CML

11, 12, 17, 18, 19, 20, 21

CRT

1, 2, 3, 4

CUP

2, 3, 5, 7, 8

DET

1, 3, 4, 5, 6, 7, 12, 13, 14, 24, 28, 33

GEM

4

INI

1, 9

QUE

13

SCR

8, 20

SWT

4, 20, 25, 26, 45

SYS

1, 8, 13, 14, 15, 17, 48, 49, 50, 84, 90, 93, 94, 97, 98

UAP

1, 5, 6, 7, 8, 9, 15, 16, 19, 21, 22, 23, 24, 27, 28, 29, 32, 33, 35, 41, 42

US

5, 6, 31

WLT

1, 3

WRP

3, 4, 9, 11, 12, 14, 15, 16, 17

RMS error

ADC

16, 21

6 Fatal error messages

ADM

1, 2

BM

3, 49, 51, 58, 67

CML

14

CMM

1, 2, 3

DET

8, 9, 16

HVC

14

INI

7

MIS

4

QUE

1, 2, 5, 6, 11, 12

SCR

4, 5, 10, 12, 13, 15, 18

SYS

33, 52

UAP

36

US

1

Display format 5 (other)

If the display format is other than display format 1 to 4, see the following:

Information

Messages that contain the character string "SDX:" or "sfdsk:" are GDS messages.